GB
Page 46 of 62
INSTRUCTION, USE AND
MAINTENANCE MANUAL
15.1 Options menu
Press the button
to display the monitor screen
to enable/disable options as shown below:
To enable/disable individual functions, simply press
on the relevant identification icon.
Pressing such icon may involve, besides, the change
in the unit of measure from "mm" to "inch" and vice
versa (where applicable) or access to a sub-screen for
values settings values (see Par. 15.1.1 or 15.1.2). After
you select/deselect the desired options, exit the menu
by pressing push-button
.
List of available options
Enable/disable the protection guard/
spin (enabled by default).
Enable/disable distance/diameter de-
tection caliper (disabled by default).
Enable/disable the display of static
threshold after each spin (enabled by
default).
It allows you to set the thresholds for
each of the balancing mode weights
(see Par. 15.1.1).
Enable/disable the lock function for
caliper arm in position (disabled by
default).
Enable/disable the ultrasound
sensor laser positioning/scanning func-
tion (enabled by default).
It allows you to change the unit of meas-
urement of the weights from grams to
ounces and vice versa.
It allows to enable/disable the width
function (enabled by default).
Enable/disable the ECO-WEIGHT func-
tion (enabled by default).
Enable/disable the positioning of
weights at "6 o'clock" (disabled by
default).
Enable/disable the pneumatic brake
after the spin (disabled by default).
It enables the weights hidden behind
spokes mode in automatic.
After the scanning, the machine places
the wheel for the fitting of the weight
behind the first spoke (spokes posi-
tion detected by the scan) (disabled
by default).
LIBRAK380.3DTEC - LIBRAK380P.3DTEC - LIBRAK430.3DTEC - LIBRAK430P.3DTEC