Safety Instructions
This appliance shall only be used in an above ground open air situation with
natural ventilation, without stagnant areas, where gas leakage and products of
combustion are rapidly dispersed by wind and natural convection.
FIGURE D1
– Outdoor Area Example 1.
An enclosure with walls on all sides, but no
overhead cover.
FIGURE D4
– Outdoor Area Example 4. With the
open side at least 25% of total wall area and
30% or more in the total of the remaining wall
area is open and unrestricted.
FIGURE D5
– Outdoor Area Example 5. With the
open side at least 35% of the total wall area
and 30% or more in total of the remaining wall
area is open and unrestricted. In the case of
balconies, 20% or more of the total wall area
shall remain open and unrestricted.
FIGURE D2
– Outdoor Area Example 2
Within a partial enclosure that includes an
overhead cover and no more than two walls.
FIGURE D3
– Outdoor Area Example 3.
With both ends open.
The following figures are diagrammatical representations of outdoor areas
suitable for use with this appliance. Rectangular areas have been used
in these figures – the same principles apply to any other shaped areas.
Any enclosure in which the appliance is used shall comply with one of the
following:
Open side at
least 25% of
total wall area
Open side at
least 25% of
total wall area
Both ends open
30 percent or more in total
of the remaining wall area
is open and unrestricted.
30 percent or more in
total of the remaining
wall area is open and
unrestricted.