background image

 

 
Congratulations on your purchase of a Bushman DC-L fridge. Please read these instructions carefully 
before installation and use. 
 

Please be safe and use common sense and caution when installing, operating and cleaning this appliance. If 
you are unsure about any of these instructions, contact your local dealer before proceeding. 
 

IMPORTANT INFORMATION 

 

 

 

 

 

 

Do not lay your fridge on its back, top or sides or at any angle exceeding 30º. If your fridge has been 
incorrectly handled, ensure that the fridge is placed in a level upright position for 12 hours to allow the internal 
fluids to redistribute evenly. 
Never operate your fridge directly from a 240 V or AC power supply. 
Do not use a modified sine wave inverter to operate your fridge. 
 
 

PRIOR TO INSTALLATION 

 

 

 

 

 

 

DELIVERY 

At delivery, please check that the fridge is complete and is not damaged in any way. Remove all packaging 
and securing tapes from the fridge. To avoid injury and causing damage to the appliance, be extremely 
cautious when using sharp or pointed tools to complete this task. 
 
Do not connect an appliance that has been damaged, contact your local stockist immediately. 
 
 

INSTALLATION 

 

 

 

 

 

 

 

Installation of the DC-L range of fridges must be completed by a suitably trained professional only. 
 

POWER SUPPLY 

Your fridge must be connected to a stable and regulated 12 V or 24 V DC power supply only. The compressor 
will automatically detect which voltage is present adjust accordingly.  
If you are using a generator or other power supply, the output must be a pure sine wave. Any fluctuations in 
generator current may damage the compressor. 

 
 

WIRING 

For optimum results, you will need the correct sized wire depending on the distance from your power supply 
to the fridge. Wiring must be directly from your fridge to your battery and should be continuous without joins. 
Please also ensure the earth is wired directly to your battery, not to a chasse. If your wiring is insufficient, your 
fridge may not perform correctly or may be even be damaged. 
 
 

CROSS 

SECTION 

IN MM2 

MAXIMUM LENGTH OF WIRE IN 

METRES 

12 V 

24 V 

2.5 

2.5 

12 

10 

10 

20 

 
 
Any switches must have a breaking load not less than 20 A on 12 V or 10 A on 24 volts. 

 

 

 

Ensure the wiring polarity is correct. Connect the red wire to the positive terminal (+) and the black wire to the 
negative terminal (-). 
 
Never connect bare electric wires. Use only connections of a size suitable for the cross section of the wire 
being used. 
 
 

Summary of Contents for DC-L Series

Page 1: ...User Manual Operating Instructions DC L Series CARAVAN MARINE RV OFFGRID ...

Page 2: ...ockist immediately INSTALLATION Installation of the DC L range of fridges must be completed by a suitably trained professional only POWER SUPPLY Your fridge must be connected to a stable and regulated 12 V or 24 V DC power supply only The compressor will automatically detect which voltage is present adjust accordingly If you are using a generator or other power supply the output must be a pure sin...

Page 3: ...RMOSTAT Turn the thermostat knob around from 0 to power up the fridge The cooling level can be set between 1 and 7 7 is the coldest setting and 1 is the warmest EQUALISING THE FRIDGE During the first 24 hours of operation your compressor will operate for longer than usual This process allows the internal air temperature food drinks condenser and insulation to equalise ENERGY SAVING TIPS Have a muc...

Page 4: ...ocate main door onto the bottom hinge Affix middle hinge to fridge cabinet Only tighten screws finger tight Locate freezer door onto the middle hinge Affix top hinge to fridge cabinet Only tighten screws finger tight Align the freezer door until it is square with the fridge cabinet Tighten top hinge screws fully Align the main door until it is square with the fridge cabinet Tighten bottom hinge sc...

Page 5: ...evel to drop by as much as 2 V This occurs especially if the wiring in insufficient or if there is a loose connection somewhere If this occurs your fridge may exhibit a continuous start stop start pattern If so have your wiring checked by an electrician when under a 10 A load GENERAL TROUBLESHOOTING Check Correct power supply The built in fuse The voltage to the compressor is still 12V when a 10 A...

Page 6: ......

Page 7: ...Exterior Ventilation Interior Ventilation Option 1 Interior Ventilation Option 3 min 300cm2 min 50mm min 50mm min 50mm Interior Ventilation Option 4 Interior Ventilation Option 2 min 300cm2 min 200mm min 50mm min 50mm min 200mm ...

Page 8: ...stomer This warranty does not apply to damage or wear to the product caused by accident abuse misuse neglect unauthorized alteration or repair or if the product was not used in accordance with Bushman printed installation and operating instructions To obtain service under this warranty the defective product must be returned to Bushman together with a copy of the original purchase receipt Any produ...

Reviews: