background image

 

 

INSTALLATION IN A CAVITY WITH THE MOUNTING KIT 

DC-L fridges are designed to be installed in a cavity. We recommend allowing a minimum 5mm gap in width 
and height for ease of installation. A minimum gap of 50mm is recommended for the rear. Refer to the 
following table for the recommended cut-out dimensions.

 

 

MODEL 

CUT-OUT CAVITY DIMENSIONS (MM) 

WIDTH

 

DEPTH

 

HEIGHT

 

DC190-L 

605 

575 

1385 

DC285-L 

605 

675 

1555 

 
VENTILATION 

Two vents need to be provided from the rear of the fridge cavity to the outside environment, or to the general 
area where the fridge is located. The vents should be located at the bottom and top of the fridge cavity and 
have a free cross section of at least 300cm2 each. This allows for natural thermal air flows across the 
condenser. As a general rule, the more ventilation you can provide, the better.  
 

MOUNTING KIT 

The mounting kit is first affixed to the side and top of the fridge cabinet using the screws provided. 
 
Once the fridge has been connected to the power supply and moved into its final position, the mounting kit 
can be affixed to the front of the cavity. 
 
 

OPERATING THE FRIDGE  

 

 

 

 

 

THERMOSTAT 

 

Turn the thermostat knob around from 0 to power up the fridge. 

 

The cooling level can be set between 1 and 7. 

 

7 is the coldest setting and 1 is the warmest.  

 

EQUALISING THE FRIDGE 

During the first 24 hours of operation, your compressor will operate for longer than usual. This process allows 
the internal air temperature, food, drinks, condenser and insulation to equalise.  
 

ENERGY SAVING TIPS 

 

Have a much ventilation as possible – the more the better. 

 

Keep the fridge out of direct sunlight whenever possible 

 

Only open the fridge or freezer door when necessary 

 

Allow hot food to cool down before placing inside the fridge 

 

Defrost the fridge as soon as a layer of ice forms 

 

Set the fridge to be only as cold as necessary 

 

CLEANING   

 

 

 

 

 

 

 

Wash the inside of your fridge with luke warm water and a mild soap. Never use abrasive or corrosive 
cleaning agents, steel wool or scouring sponges. A soft sponge, towel, or soft brush is recommended. 
 
Always keep the inside of the fridge clean and dry. Remove any condensate water or ice which gathers in or 
near the tray under the freezer compartment. 
 
Be careful when opening or closing the freezer door if ice has been allowed to accumulate in this area. 
 
Keep the doors of the fridge ajar when the fridge is not in use, to allow fresh air to circulate inside the fridge 
compartment. 
 
 
 
 
 

Summary of Contents for DC-L Series

Page 1: ...User Manual Operating Instructions DC L Series CARAVAN MARINE RV OFFGRID ...

Page 2: ...ockist immediately INSTALLATION Installation of the DC L range of fridges must be completed by a suitably trained professional only POWER SUPPLY Your fridge must be connected to a stable and regulated 12 V or 24 V DC power supply only The compressor will automatically detect which voltage is present adjust accordingly If you are using a generator or other power supply the output must be a pure sin...

Page 3: ...RMOSTAT Turn the thermostat knob around from 0 to power up the fridge The cooling level can be set between 1 and 7 7 is the coldest setting and 1 is the warmest EQUALISING THE FRIDGE During the first 24 hours of operation your compressor will operate for longer than usual This process allows the internal air temperature food drinks condenser and insulation to equalise ENERGY SAVING TIPS Have a muc...

Page 4: ...ocate main door onto the bottom hinge Affix middle hinge to fridge cabinet Only tighten screws finger tight Locate freezer door onto the middle hinge Affix top hinge to fridge cabinet Only tighten screws finger tight Align the freezer door until it is square with the fridge cabinet Tighten top hinge screws fully Align the main door until it is square with the fridge cabinet Tighten bottom hinge sc...

Page 5: ...evel to drop by as much as 2 V This occurs especially if the wiring in insufficient or if there is a loose connection somewhere If this occurs your fridge may exhibit a continuous start stop start pattern If so have your wiring checked by an electrician when under a 10 A load GENERAL TROUBLESHOOTING Check Correct power supply The built in fuse The voltage to the compressor is still 12V when a 10 A...

Page 6: ......

Page 7: ...Exterior Ventilation Interior Ventilation Option 1 Interior Ventilation Option 3 min 300cm2 min 50mm min 50mm min 50mm Interior Ventilation Option 4 Interior Ventilation Option 2 min 300cm2 min 200mm min 50mm min 50mm min 200mm ...

Page 8: ...stomer This warranty does not apply to damage or wear to the product caused by accident abuse misuse neglect unauthorized alteration or repair or if the product was not used in accordance with Bushman printed installation and operating instructions To obtain service under this warranty the defective product must be returned to Bushman together with a copy of the original purchase receipt Any produ...