Care and maintenance
Looking after your appliance
Care and maintenance
or online at
www.
CVTI
-
support.c
om
If you still require further assistance, call one of our experts on
01759 487838
G30 29mbar 7.5 kW 545 g/h
II2H3+ GB Clase: 3
NG
G20 20 mbar
LPG
G30 29mbar
RAPID BURNER
DIA. of INJECTOR (1/100mm)
115
85
NOMINAL RATING (KW)
3
3
CONSUMPTION
286 l/h
218g/h
SEMI-RAPID BURNER
DIA. of INJECTOR (1/100mm)
97
65
NOMINAL RATING (KW)
1,75
1,75
CONSUMPTION
167 l/h
127g/h
SEMI-RAPID BURNER
DIA. of INJECTOR (1/100mm)
97
65
NOMINAL RATING (KW)
1,75
1,75
CONSUMPTION
167 l/h
127 g/h
AUXILIARY BURNER
DIA. of INJECTOR (1/100mm)
72
50
NOMINAL RATING (KW)
1
1
CONSUMPTION
95 l/h
73g/h
Injector Table
Technical Specification
Summary of Contents for LSBGHP
Page 1: ...Instruction manual Bulit in Gas Hob LSBGHP...
Page 4: ......
Page 5: ...Safety information...
Page 8: ......
Page 9: ...Getting to know yoVS VJMU JO BT PC...
Page 13: ...Installing your VJMU JO BT PC...
Page 19: ...Using your VJMU JO BT PC...
Page 21: ...Care and maintenance...
Page 25: ...Product support 6...