- Electrical connections must be
carried out by a suitably qualifi ed person and in
accordance with all relevant local building and
installation regulations.
Electrical connections
This appliance is designed to be connected
1.
to an earthed electrical mains supply.
The appliance must be connected to a
2.
double pole switched Fuse Connection Unit
(FCU) with a minimum rating of 32 A and
a minimum contact clearance of 3mm in
accordance with IEE regulations.
Make sure the switched FCU is located
3.
adjacent to the appliance within a maximum
distance of 2m. The switched FCU
must
not
be located above the appliance but
should be easily accessible in case of an
emergency.
The switched FCU must be connected to
4.
the mains consumer unit using a single
spur.
Do not
connect the switched FCU to
the lighting or socket spurs.
Connections should be made via an
5.
electrical cable of H05W-F specifi cation or
better.
Suffi cient electrical cable should be used to
6.
allow the appliance to be withdrawn from
the wall.
Make sure all electrical cabling is routed to
7.
prevent trapping.
Make sure the electrical cable is not in
8.
contact with any hot parts of the appliance
once it is in position to avoid danger of
melting and electrical short circuit.
The terminal box on the rear of the
9.
appliance can be accessed by removing
the cover using suitable tools.
Connect one end of the electrical cable to
10.
the terminals on the rear of the appliance
following the connection diagram shown in
fi gure 3.
Connect the remaining end of the electrical
11.
cable to the switched FCU following the
connection diagram shown in fi gure 4.
Installation
Customer Helpline
0845 600 4632
Positioning & electrical connection
Figure 3
Figure 4
Neutral
Neutral
From supply
All earth wires
must be sleeved
and terminated to
back box
To appliance
Earth
Earth
Live
Live