CAUTION
_a
Disregard of this safety note may lead to accidents with minor inju-
ries or property damage.
Noise Emission
For the sound pressure level in free field according to EN ISO 2151
Ú
page 15: Technical Data.
Transport
Transport in Packaging
Vacuum and pressure pumps individually packed in cardboard boxes
can be carried by hand.
Packed on a pallet the vacuum and pressure pump is to be transported
with a forklift.
Transport without Packaging
In case the vacuum and pressure pump is packed in a cardboard box
with inflated cushions:
◆
Remove the inflated cushions from the box
In case the vacuum and pressure pump is in a cardboard box cushioned
with rolled corrugated cardboard:
◆
Remove the corrugated cardboard from the box
In case the vacuum and pressure pump is laid in foam:
◆
Remove the foam
Version without handle:
◆
Grasp the vacuum and pressure pump with both hands
Version with handle:
◆
Carry the vacuum and pressure pump using the handle
Storage
Short-term Storage
●
Make sure that the suction connection/gas inlet and the gas dis-
charge/pressure connection are closed (leave the provided plugs
in)
●
Store the vacuum and pressure pump
–
if possible in original packaging,
–
indoors,
–
dry,
–
dust free and
–
vibration free
Conservation
In case of adverse ambient conditions (e.g. aggressive atmosphere, fre-
quent temperature changes) conserve the vacuum and pressure pump
immediately. In case of favourable ambient conditions conserve the
vacuum and pressure pump if a storage of more than 3 months is
scheduled.
●
Make sure that all ports are firmly closed; seal all ports that are not
sealed with PTFE-tape, gaskets or o-rings with adhesive tape
Note
: VCI stands for “volatile corrosion inhibitor”. VCI-products (film,
paper, cardboard, foam) evaporate a substance that condenses in mo-
lecular thickness on the packed good and by its electro-chemical prop-
erties effectively suppresses corrosion on metallic surfaces. However,
VCI-products may attack the surfaces of plastics and elastomers. Seek
advice from your local packaging dealer! Busch uses CORTEC
VCI 126 R film for the overseas packaging of large equipment.
●
Wrap the vacuum and pressure pump in VCI film
●
Store the vacuum and pressure pump
–
if possible in original packing,
–
indoors,
–
dry,
–
dust free and
–
vibration free.
For commissioning after conservation:
●
Make sure that all remains of adhesive tape are removed from the
ports
●
Commission the vacuum and pressure pump as described in the
chapter Installation and Commissioning (
Ú
page 4)
Installation and
Commissioning
Installation Prerequisites
CAUTION
_a
In case of non-compliance with the installation prerequisites, partic-
ularly in case of insufficient cooling:
Risk of damage or destruction of the vacuum and pressure pump
and adjoining plant components!
Risk of injury!
The installation prerequisites must be complied with.
●
Make sure that the integration of the vacuum and pressure pump
is carried out such that the essential safety requirements of the
Machine Directive 2006/42/EC are complied with (in the responsi-
bility of the designer of the machinery into which the vacuum and
pressure pump is to be incorporated;
Ú
page 14: note in the
EC-Declaration of Conformity)
Mounting Position and Space
●
Make sure that the environment of the vacuum and pressure
pump is not potentially explosive
●
Make sure that the following ambient conditions will be complied
with:
–
ambient temperature: –10 ... +40 °C
–
ambient pressure: atmospheric
●
Make sure that the environmental conditions comply with the pro-
tection class of the drive motor (according to the nameplate)
●
Make sure that the vacuum and pressure pump will be placed or
mounted horizontally
●
Make sure that the base for placement / mounting base is even
●
Make sure that in order to warrant a sufficient cooling there will be
a clearance of minimum 2 cm between the vacuum and pressure
pump and nearby walls
●
Make sure that no heat sensitive parts (plastics, wood, cardboard,
paper, electronics) will touch the surface of the vacuum and
pressure pump
●
Make sure that the installation space or location is vented such
that a sufficient cooling of the vacuum and pressure pump is war-
ranted
Transport
SV
1005
C / SD
1005
C / SV
1008
C / SD
1008
C
0870135648
page 4
Summary of Contents for SECO SD 1005 C
Page 12: ...Exploded View Exploded View page 12 SV 1005 C SD 1005 C SV 1008 C SD 1008 C 0870135648 ...
Page 17: ......
Page 18: ......
Page 19: ......