Version with three-phase motor:
The vacuum and pressure pump runs in the
wrong direction
Verification and rectification
Ú
page 4: Instal-
lation and Commissioning
Foreign objects in the vacuum and pressure
pump
Broken vanes (35)
Stuck bearings
Repair the vacuum and pressure pump (Busch
service)
The vacuum and pressure pump runs very
noisily
Defective bearings
Repair the vacuum and pressure pump (Busch
service)
Stuck vanes (35)
Repair the vacuum and pressure pump (Busch
service)
The vacuum and pressure pump runs very hot
Insufficient air ventilation
Make sure that the cooling of the vacuum and
pressure pump is not impeded by dust/dirt
Clean the fan cowling, the fan wheel, the ven-
tilation grille and the cooling fins
Install the vacuum and pressure pump in a
narrow space only if sufficient ventilation is
ensured
Ambient temperature too high
Observe the permitted ambient temperatures
Temperature of the inlet gas too high
Observe the permitted temperatures for the
inlet gas
Mains frequency or voltage outside tolerance
range
Provide a more stable power supply
Partial clogging of filters or screens
Partial clogging in the suction, discharge or
pressure line
Remove the clogging
Long suction, discharge or pressure line with
too small diameter
Use larger diameter
Troubleshooting
SV
1005
C / SD
1005
C / SV
1008
C / SD
1008
C
0870135648
page 11
Summary of Contents for SECO SD 1005 C
Page 12: ...Exploded View Exploded View page 12 SV 1005 C SD 1005 C SV 1008 C SD 1008 C 0870135648 ...