Installation | 5
Instruction Manual R5 RU 0050-0070 B_EN_en
11 | 36
5.2
Connecting Lines / Pipes
●
Remove all protective covers before installation.
●
Make sure that the connection lines cause no stress on the machine‘s connection; if necessary use
flexible joints.
●
Make sure that the line size of the connection lines over the entire length is at least as large as
the connections of the machine.
In case of long connection lines it is advisable to use larger line sizes in order to avoid a loss of effi-
ciency. Seek advice from your Busch representative.
5.2.1
Suction Connection
WARNING
Unprotected suction connection.
Risk of severe injury!
●
Keep long hair, loose articles of clothing, etc. away from suction connection.
NOTICE
Ingress of foreign objects or liquids.
Risk of damage to the machine!
If the inlet gas contains dust or other foreign solid particles:
●
Install a suitable filter (5 micron or less) upstream from the machine.
Connection size(s):
– ISO-KF 40
5.2.2
Discharge Connection
CAUTION
The discharge gas contains small quantities of oil.
Risk to health!
If air is discharged into rooms where persons are present:
●
Make sure that sufficient ventilation is provided.
NOTICE
Discharge gas flow obstructed.
Risk of damage to the machine!
●
Make sure that the discharged gas will flow without obstruction. Do not shut off or throttle the
discharge line or use it as a pressurized air source.
Connection size(s):
– ISO-KF 25