Maintenance | 8
Instruction Manual R5 RU 0050-0070 B_EN_en
19 | 36
NOTICE
Using inappropriate cleaners.
Risk of removing safety stickers and protective paint!
●
Do not use incompatible solvents to clean the machine.
●
Shut down the machine and lock against inadvertent start up.
●
Vent the connected lines to atmospheric pressure.
If necessary:
●
Disconnect all connections.
DANGER
Maintenance work without disconnecting the variable speed drive.
Risk of electrical shock.
●
Disconnect and isolate the variable speed drive before attempting any work on it.
High voltages are present at the terminals and within the variable speed drive for up to 10 min-
utes after disconnection of the electrical supply.
●
Always ensure by using a suitable multimeter that no voltage is present on any drive power termi-
nals prior to commencing any work.
DANGER
Live wires. Carry out any work on the variable speed drive and motor.
Risk of electrical shock!
●
Electrical installation work must only be executed by qualified personnel.
8.1
Maintenance Schedule
The maintenance intervals depend very much on the individual operating conditions. The intervals
given below are considered as starting values which should be shortened or extended as appropri-
ate. Particularly harsh applications or heavy duty operation, such as high dust loads in the environ-
ment or in the process gas, other contamination or ingress of process material, can make it neces-
sary to shorten the maintenance intervals significantly.
Interval
Maintenance work
Weekly
●
●
Check the machine for oil leaks - in case of leaks have the
machine repaired (contact Busch).
Every 6 months
●
Clean the machine from dust and dirt.
●
Make sure that the electronic components and the cooling
fan are free from dust.
Yearly
●
Change the exhaust filters (EF), see
Every 8000 hours
●
20].