Decommissioning | 9
0870573103_RA0160-0302D_O2_-0001_IM_en
23 / 28
9
Decommissioning
• Shut down the machine and lock against inadvertent start up.
• Vent the connected lines to atmospheric pressure.
Version with water-oil heat exchanger:
• Turn off the water supply.
• Disconnect the water supply.
• Open the water by-pass valve (WBV).
• Blow through the water cooling inlet with compressed air.
• Disconnect all connections.
If the machine is going to be stored:
• See
Storage [
}
8]
.
9.1 Dismantling and Disposal
• Drain the oil.
• Remove the exhaust filters.
• Remove the oil filter.
• Separate special waste from the machine.
• Dispose of special waste in compliance with applicable regulations.
• Dispose of the machine as scrap metal.
10 Spare Parts
NOTICE
Use of non-Busch genuine spare parts.
Risk of premature failure!
Loss of efficiency!
• The exclusive use of Busch genuine spare parts and consumables is recommended for
the proper function of the machine and for granting of warranty.
WARNING
Use of non-Busch genuine spare parts.
Risk of fire!
• Only use Busch spare parts approved by Busch and suitable for oxygen application.
Spare parts kit
Description
Part no.
Service kit
(RA 0160 / 0202 D “O2”)
Includes all the necessary parts for main-
tenance.
0992 537 264
Service kit
(RA 0250 / 0302 D “O2”)
Includes all the necessary parts for main-
tenance.
0992 537 265
If other parts are required:
• Contact your Busch representative for the detailed spare parts list.