Installation | 5
0870573103_RA0160-0302D_O2_-0001_IM_en
11 / 28
5.2.2 Discharge Connection
CAUTION
The discharge gas contains small quantities of oil.
Risk to health!
If air is discharged into rooms where persons are present:
• Make sure that sufficient ventilation is provided.
Connection size:
– G2
Depending on the specific order, other connection dimensions may apply.
• Make sure that the discharged gas will flow without obstruction. Do not shut off or
throttle the discharge line or use it as a pressurised air source.
Unless the aspirated air is discharged to the environment right at the machine:
• Make sure that the discharge line either slopes away from the machine or provide a li-
quid separator or a siphon with a drain cock, so that no liquids can flow back into the
machine.
5.2.3 Cooling Water Connection (Optional)
Water-oil heat exchanger without inlet accessories
WHE
CWO
CWI
CWO
TV
PSA
WBV
WF
CWI
WHE
Water-oil heat exchanger with inlet accessories
CWI
Cooling water inlet
PSA
Pressure switch
CWO
Cooling water outlet
WBV
Water bypass valve
WHE
Water-oil heat exchanger
WF
Water filter
TV
Thermostatic valve
The factory default adjustment of the thermostatic valve (TV) is set in position 2 (approx.
75°C oil temperature).
Connection size:
– 19 mm hose (CWI / CWO)
• Make sure that the cooling water complies with the following requirements:
Min. supply capacity
l/min
2.5
Water pressure
bar
2 ... 6