5 | Installation
14 / 28
0870573103_RA0160-0302D_O2_-0001_IM_en
Delta connection, multi-voltage motor
with 12 pins (middle voltage):
4
4
4
NOTICE
Incorrect direction of rotation.
Risk of damage to the machine!
• Operation in the wrong direction of rotation can destroy the machine in a short time!
Prior to start-up, ensure that the machine is operated in the right direction.
• Determine the intended direction of rotation with the arrow (stuck on or cast).
• Jog the motor briefly.
• Watch the fan wheel of the motor and determine the direction of rotation just before
the fan wheel stops.
If the rotation must be changed:
• Switch any two of the motor phase wires.
5.5 Electrical Connection of the Monitoring Devices
NOTE
In order to prevent potential nuisance alarms, Busch recommends that the control system
is configured with a time delay of at least 10 seconds.
5.5.1 Wiring Diagram Temperature Switch (Optional)
Part no.:
0651 563 747
Connector:
M12x1, 4-pin
U =
≤
250 V AC/DC (50/60 Hz) ; I =
≤
1 A
Switch point:
T
1
pin 1 + 2 = 110 °C*
T
2
pin 3 + 4 = 130 °C*
1
2
4
3
2
1
T
1
4
3
T
2
1 = Brown ; 2 = White ;
3 = Blue ; 4 = Black
*
The switch point value depends on the oil type, see
Oil [
}
26]
.
5.5.2 Wiring Diagram Resistance Thermometer (Optional)
Part no.:
0651 563 753
Connector:
M12x1, 4-pin
U = 10 … 35 VDC
4 ... 20 mA
►
0 ... 150 °C
Warning / trip signals:
see
Oil [
}
26]
.
1
2
4
3
3
1
+
-
1 = Brown ; 3 = Blue