15 EU Declaration of Conformity

This Declaration of Conformity and the CE-mark affixed to the nameplate are valid for the machine within the
Busch scope of delivery. This Declaration of Conformity is issued under the sole responsibility of the manufacturer.
When this machine is integrated into a superordinate machinery the manufacturer of the superordinate machinery
(this can be the operating company, too) must conduct the conformity assessment process for the superordinate
machine or plant, issue the Declaration of Conformity for it and affix the CE-mark.

The manufacturer

Ateliers Busch S.A.
Zone Industrielle
CH-2906 Chevenez

declares that the machine(s): 

PANDA WZ 3600 A

has (have) been manufactured in accordance with the European Directives:

– ‘Machinery’ 2006/42/EC

– ‘Electromagnetic Compatibility’ 2014/30/EU

– ‘RoHS’ 2011/65/EU

and the following standards:

Standard

Title of the Standard

EN ISO 12100 : 2010

Safety of machinery - Basic concepts, general principles of design

ISO 13857 : 2019

Safety of machinery - Safety distances to prevent hazard zones being reached
by the upper and lower limbs

EN 1012-1 : 2010
EN 1012-2 : 1996 + A1 : 2009

Compressors and vacuum pumps - Safety requirements - Part 1 and Part 2

EN ISO 2151 : 2008

Acoustics - Noise test code for compressors and vacuum pumps - Engineering
method (grade 2)

IEC 60204-1 : 2016

Safety of machinery - Electrical equipment of machines - Part 1: General re-
quirements

IEC 61000-6-2 : 2016

Electromagnetic compatibility (EMC) - Generic standards. Immunity for indus-
trial environments

IEC 61000-6-4 : 2018

Electromagnetic compatibility (EMC) - Generic standards. Emission standard
for industrial environments

EN ISO 13849-1 : 2015 

(1)

Safety of machinery - Safety-related parts of control systems - Part 1: General
principles for design

(1)

In case control systems are integrated.

Person authorised to compile the technical file:

Gerd Rohweder
Busch Dienste GmbH
Schauinslandstr. 1
DE-79689 Maulburg

Chevenez, 16.04.2021

Christian Hoffmann, General Director

Summary of Contents for PANDA WZ 3600 A

Page 1: ...nstruction manuals service kits Instruction Manual PANDA Vacuum Booster WZ 3600 A 0870203785 0001_en Original instructions Modifications reserved 10 05 2021 Ateliers Busch S A Zone industrielle 2906 C...

Page 2: ...ter Connection 9 5 3 Filling Oil 11 5 4 Electrical Connection 12 5 4 1 Wiring Diagram Three Phase Motor 13 5 5 Electrical Connection of the Monitoring Devices 14 5 5 1 Wiring Diagram Temperature Switc...

Page 3: ...designed and manufactured according to state of the art meth ods Nevertheless residual risks may remain This instruction manual highlights potential hazards where appropriate Safety notes and warning...

Page 4: ...I Cooling water inlet CWO Cooling water outlet CWC Cooling water connection EB Eye bolt IN Suction connection MP Magnetic plug MTB Motor terminal box NP Nameplate ODP Oil drain plug OFP Oil fill plug...

Page 5: ...of air and other dry non aggressive non toxic and non explosive gases Conveying of other media leads to an increased thermal and or mechanical load on the machine and is permissible only after a consu...

Page 6: ...ed motor 2 3 2 Temperature Switch The temperature switch monitors the oil temperature of the machine The machine must be stopped when the temperature switch trips 140 C 3 Transport WARNING Suspended l...

Page 7: ...ng preferably at temperatures between 20 55 C 5 Installation 5 1 Installation Conditions NOTICE Use of the machine outside of the permitted installation conditions Risk of premature failure Loss of ef...

Page 8: ...ke sure that the cooling water complies with the requirements see Cooling Water Connection 9 5 2 Connecting Lines Pipes Remove all protective covers before installation Make sure that the connection l...

Page 9: ...ream from the machine Connection size s DN160 DIN 28404 Depending on the specific order other connection dimensions may apply 5 2 3 Discharge Connection Connection size s DN160 DIN 28404 Connection si...

Page 10: ...the cooling water complies with the following requirements Min supply capacity l min 4 Water pressure bar 2 5 Supply temperature C 5 30 Required pressure differential across supply and return bar 1 T...

Page 11: ...inappropriate oil Risk of premature failure Loss of efficiency Only use an oil type which has previously been approved and recommended by Busch For oil type and oil capacity see Technical Data 26 and...

Page 12: ...from your Busch representative 5 4 Electrical Connection DANGER Live wires Risk of electrical shock Electrical installation work must only be executed by qualified personnel Make sure that the power...

Page 13: ...r motor and temperature switches connection instructions diagrams 5 4 1 Wiring Diagram Three Phase Motor NOTICE The tightening torque does not comply with the recommendation Risk of damage the connect...

Page 14: ...r connection low voltage Star connection high voltage 5 5 Electrical Connection of the Monitoring Devices NOTE In order to prevent potential nuisance alarms Busch recommends that the control system is...

Page 15: ...ne compression chamber Risk of damage to the machine Do not lubricate the compression chamber of the machine with oil or grease NOTICE The machine is running at 90 Hz when starting a pump down cycle R...

Page 16: ...soon as the target pressure is reached close the isolation and decrease the motor frequency to 30 Hz 6 2 Compression Chamber Flushing Depending on the process type very demanding application flushing...

Page 17: ...the machine Open the gas supply Flush the machine When the flushing is finished Close the gas supply Dry the machine of flushing fluid Do not operate the machine in normal operating conditions with th...

Page 18: ...operating conditions The intervals given below are considered as starting values which should be shortened or ex tended as appropriate Particularly harsh applications or heavy duty operation such as h...

Page 19: ...sk of explosion If the oil becomes dark Contact your Busch representative without delay Make sure that the oil is either light or transparent If the oil becomes dark or looks different from the initia...

Page 20: ...ce 20 28 0870203785_WZ3600A_ 0001_IM_en 1 5 2 3 2x 4 Drain pan Cleaning cloth Oil draining at the motor side Magnetic plug Magnetic plug 1 3 2 Drain pan Cleaning cloth Oil draining at the gear side Ma...

Page 21: ...0001_IM_en 21 28 For oil type and oil capacity see Technical Data 26 and Oil 26 1 4 3 MAX MIN 2 B u s c h O i l Check oil level Oil filling at the motor side 1 4 3 MAX MIN 2 B u s c h O i l Check oil...

Page 22: ...Wear appropriate personal protective equipment NOTICE Improper assembly Risk of premature failure Loss of efficiency It is highly recommended that any dismantling of the machine that goes beyond any...

Page 23: ...the machine as scrap metal 10 Spare Parts NOTICE Use of non Busch genuine spare parts Risk of premature failure Loss of efficiency The exclusive use of Busch genuine spare parts and consumables is re...

Page 24: ...r lines Seek advice from your local Busch representa tive The backing pump is not correctly defined Contact Busch The machine runs in the wrong direction Check the direction of ro tation see Wiring Di...

Page 25: ...is black Oil change intervals are too long Drain the oil and fill in new oil see Oil Change 19 The machine runs too hot See problem The ma chine runs too hot For the solution of problems not mentioned...

Page 26: ...0 Hz Blower nominal suction capacity m3 h 3600 Backing pump nominal suction capacity m3 h 720 360 360 Delta P max in continuous operation hPa 30 15 On request Delta P max in 50 duty hPa 30 15 On reque...

Page 27: ...tandards Standard Title of the Standard EN ISO 12100 2010 Safety of machinery Basic concepts general principles of design ISO 13857 2019 Safety of machinery Safety distances to prevent hazard zones be...

Page 28: ...Japan info busch co jp Korea busch busch co kr Malaysia busch busch com my Mexico info busch com mx Netherlands info busch nl New Zealand sales busch co nz Norway post busch no Peru info busch com pe...

Reviews: