5 | Installation
10 / 28
0870133276_MM1324_1322AV_A0005_IM_en_MD
• Make sure that the environmental conditions comply with the protection class of the
motor and the electrical instruments.
• Make sure that the installation space or location is vented such that sufficient cool-
ing of the machine is provided.
• Make sure that cooling air inlets and outlets are not covered or obstructed and that
the cooling air flow is not affected adversely in any other way.
• Make sure that the oil sight glass (OSG) remains easily visible.
• Make sure that enough space remains for maintenance work.
• Make sure that the machine is placed or mounted horizontally, a maximum of 1° in
any direction is acceptable.
.
• Make sure that all provided covers, guards, hoods, etc. are mounted.
If the machine is installed at an altitude greater than 1000 meters above sea level:
• Contact your Busch representative, the motor should be derated or the ambient
temperature limited.
5.2 Connecting Lines / Pipes
WARNING
Rotating Parts.
Risk of severe injury!
• Do not operate the machine without suction / discharge connection installed.
• Remove all protective covers before installation.
• Make sure that the connection lines cause no stress on the machine‘s connection; if
necessary use flexible joints.
• Make sure that the line size of the connection lines over the entire length is at least
as large as the connections of the machine.
In case of long connection lines it is advisable to use larger line sizes in order to avoid
a loss of efficiency. Seek advice from your Busch representative.
5.2.1 Suction Connection
NOTICE
Ingress of foreign objects or liquids.
Risk of damage to the machine!
If the inlet gas contains dust or other foreign solid particles:
• Install a suitable filter (5 micron or less) upstream from the machine.
Connection size(s):
– G2
Depending on the specific order, other connection dimensions may apply.
5.2.2 Discharge Connection
Connection size(s):
– R1 for MM 1324 AV, MM 1202 AV, MM 1252 AV
– R1 1/4 for MM 1322 AV