7 | Commissioning
20 | 40
Instruction Manual DOLPHIN LM 0100-0800 A, LT 0130-0750 A_EN_en
7
Commissioning
CAUTION
During operation the surface of the machine may reach temperatures of more than 70°C.
Risk of burns!
●
Avoid contact with the machine during and directly after operation.
NOTICE
The machine is running without operating liquid system.
Will ruin the machine in short time!
●
Prior to commissioning, the operating liquid system must be connected and open.
●
Make sure that the installation conditions (see
9]) are met.
Before operating the machine:
●
Make sure that the operating liquid level is at the machine shaft center.
●
Check the operation of all automatic valves before start up
●
Switch on the machine.
●
Make sure that the maximum permissible number of starts does not exceed 12 starts per hour.
Those starts should be spread within the hour.
After a few seconds of operation:
●
Turn on/activate the operating liquid system device.
●
Make sure that the operating conditions comply with the
As soon as the machine is operated under normal operating conditions:
●
Measure the motor current and record it as reference for future maintenance and trouble-
shooting work.