Maintenance | 8
Instruction Manual DOLPHIN LM 0100-0800 A, LT 0130-0750 A_EN_en
23 | 40
8.1
Maintenance Schedule
The maintenance intervals depend very much on the individual operating conditions. The intervals
given below are considered as starting values which should be shortened or extended as appropri-
ate. Particularly harsh applications or heavy duty operation, such as high dust loads in the environ-
ment or in the process gas, other contamination or ingress of process material, can make it neces-
sary to shorten the maintenance intervals significantly.
Interval
Maintenance work
Monthly
●
●
Check for excessive vibration, see Operating Conditions.
●
Check the operating liquid temperature, see
11].
●
Check the machine for liquid leaks - in case of leaks have
the machine repaired (contact Busch).
Every 1000 operating hours*
●
Regrease the bearings (add 15g of lithium based grease
NLGI class 2 to each bearing).
Every year
●
Carry out a visual inspection on the machine to check for
dust and dirt. Avoid using any cleaning products which may
result in damage to the pump label or paint.
If an inlet screen is installed:
●
Check it and clean if necessary.
Every 5 years
●
Have a major overhaul (contact Busch).
* For DOLPHIN LM 0800 A, LT 0630-0750 A only. Smaller DOLPHIN LM/LT use bearings which are
greased for life.