Troubleshooting | 11
0870222540_NX0950A_WCV_-_IM_en
31 / 36
The machine does not reach
the usual pressure on the
suction connection.
Suction or discharge lines
too long or section diameter
too small.
• Use larger diameter or
shorter lines.
• Seek advice from your
local Busch representa-
tive.
The inlet screen (IS) is par-
tially clogged.
• Clean the inlet screen (IS),
The machine runs in the
wrong direction.
• Check the direction of ro-
tation, see Wiring Dia-
gram Three-Phase Motor.
Internal parts are worn or
damaged.
• Repair the machine (con-
tact Busch).
The machine runs very nois-
ily.
Wrong oil quantity or un-
suitable oil type.
• Use one of the recom-
mended oils in the correct
quantity, see
Defective gears, bearings or
coupling element.
• Repair machine (contact
Busch).
The machine runs too hot.
Insufficient cooling.
• Make sure to comply with
the cooling water require-
ments, see
.
Ambient temperature too
high.
• Observe the permitted
ambient temperature, see
Temperature of the process
gases at the inlet too high.
• Observe the permitted
gas inlet temperature, see
Oil level too low.
• Top up oil.
The oil is black.
Oil change intervals are too
long.
• Drain the oil and fill in
.
The machine runs too hot.
• See problem "The ma-
chine runs too hot".
For the solution of problems not mentioned in the troubleshooting chart contact your
Busch representative.