Installation | 5
0870222540_NX0950A_WCV_-_IM_en
13 / 36
• Make sure that the counter pressure (also termed back pressure) at the discharge con-
nection (OUT) does not exceed the maximum allowable discharge pressure, see
5.2.3 Cooling Water Connection
CWI
CWO
CWI
Cooling water inlet
CWO
Cooling water outlet
• Connect the cooling water connections (CWI / CWO) to the water supply.
Connection size:
– G1/2, ISO 228-1 (CWI / CWO)
• Make sure that the cooling water complies with the following requirements:
Supply capacity
l/min
8 ... 16
Water pressure
bar
1 ... 6
Supply temperature
°C
+10 ... +30
Required pressure differential across supply
and return
bar
≥
1
• To reduce the maintenance effort and ensure a long product lifetime we recommend
the following cooling water quality:
Hardness
mg/l (ppm) < 90
Properties
Clean & clear
PH value
7 ... 8
Particle size
µm
< 200
Chloride
mg/l
< 100
Electrical conductivity
µS/cm
≤
100
Free chloride
mg/l
< 0.3
Materials in contact with the cooling water Stainless steel and cast iron
NOTE
Water hardness unit conversion.
1 mg/l (ppm) = 0.056 °dh (german degree) = 0.07 °e (english degree) = 0.1 °fH (french
degree)
Summary of Contents for COBRA NX 0950 A
Page 3: ...Table of Contents 0870222540_NX0950A_WCV_ _IM_en 3 14 EU Declaration of Conformity 33...
Page 34: ...Note...