6 | Commissioning
22 / 36
0870222540_NX0950A_WCV_-_IM_en
If the machine is equipped with a barrier gas system:
• Turn on the barrier gas supply.
• Adjust the barrier gas pressure.
• Switch on the machine.
• Make sure that the maximum permissible number of starts does not exceed 6 starts
per hour. Those starts should be spread within the hour.
• Make sure that the operating conditions comply with the
.
• After a few minutes of operation, perform an
.
As soon as the machine is operated under normal operating conditions:
• Measure the motor current and record it as reference for future maintenance and
troubleshooting work.