5 | Installation
10 / 32
Instruction Manual COBRA NC 1000 B WCV_EN_en
• Make sure that the line size of the connection lines over the entire length is at least
as large as the connections of the machine.
In case of very long connection lines it is advisable to use larger line sizes in order to
avoid a loss of efficiency. Seek advice from your Busch representative.
5.2.1 Suction Connection
WARNING
Unprotected suction connection.
Risk of severe injury!
• Do not put hand or fingers in the suction connection.
NOTICE
Ingress of foreign objects or liquids.
Risk of damage to the machine!
If the inlet gas contains dust or other foreign solid particles:
• Install a suitable filter (5 micron or less) upstream from the machine.
Connection size(s):
– DN125 PN16, EN 1092-1
If the machine is used as part of a vacuum system:
• Busch recommends the installation of an isolation valve in order to prevent the
machine from turning backwards.
5.2.2 Discharge Connection
Connection size(s):
At the machine discharge connection:
– DN125 PN16, EN 1092-1
At the silencer (SI) discharge connection (two optional versions available):
– DN125 PN16, EN 1092-1
– DN100 ISO-K, DIN 28404
• Make sure that the discharged gas will flow without obstruction. Do not shut off or
throttle the discharge line or use it as a pressurised air source.
• Make sure that the counter pressure (also termed back pressure) at the discharge
connection (OUT) does not exceed the maximum allowable discharge pressure,
see
Summary of Contents for COBRA NC 1000 B
Page 31: ...Note...