9 | Decommissioning
26 / 32
Instruction Manual COBRA NC 1000 B WCV_EN_en
9
Decommissioning
• Shut down the machine and lock against inadvertent start up.
• Turn off the water supply.
If the machine is equipped with a barrier gas system:
• Close the barrier gas supply.
• Vent the connected lines to atmospheric pressure.
• Disconnect all connections.
If the machine is going to be stored:
• See
9.1 Dismantling and Disposal
• Drain the oil.
• Drain the cooling liquid.
• Separate special waste from the machine.
• Dispose of special waste in compliance with applicable regulations.
• Dispose of the machine as scrap metal.
10 Spare Parts
NOTICE
Use of non-Busch genuine spare parts.
Risk of premature failure!
Loss of efficiency!
• The exclusive use of Busch genuine spare parts and consumables is recommended
for the correct functioning of the machine and to validate the warranty.
There is no standard spare parts kits available for this product, if you require Busch
genuine parts:
• Contact your Busch representative for the detailed spare parts list.