2 | Product Description
6 / 40
0870567092_NC0630C_WCV_A0006_IM_en
NOTE
Technical term.
In this instruction manual, we consider that the term ‘machine’ refers to the ‘vacuum
pump’.
2.1 Operating Principle
The machine works on the one-stage, twin-screw pump principle.
Two screw rotors are rotating inside the cylinder. The pumped medium is trapped
between the cylinder and screw chambers, compressed, and transported to the gas out-
let. During the compression process, the two screw rotors do not come into contact with
each other nor with the cylinder. There is no need for a lubrication or an operating fluid
in the compression chamber.
2.2 Application
The machine is intended for the suction of air and other dry, non-aggressive, non-toxic
and non-explosive gases.
Conveying of other media leads to an increased thermal and/or mechanical load on the
machine and is permissible only after a consultation with Busch.
The machine is intended for the placement in a non-potentially explosive environment.
The machine is capable of maintaining ultimate pressure, see
The machine is suitable for continuous operation.
Permitted environmental conditions, see
.
2.3 Start Controls
The machine comes without start controls. The control of the machine is to be provided
in the course of installation.
The machine can be optionally equipped with a starter unit or a variable-frequency drive.
2.4 Standard Features
2.4.1 Water Cooling
The machine is cooled by a cooling liquid circuit in the cylinder cover and cylinder.
The cooling liquid pump (CLP) allows a recirculating flow in the cooling liquid chamber.
The cooling liquid is cooled by a plate heat exchanger (PHE) which must be connected to
the water main.
Summary of Contents for COBRA NC 0600 C
Page 38: ...Note...
Page 39: ...Note...