5 | Installation
14 / 40
0870567092_NC0630C_WCV_A0006_IM_en
5.2.5 Dilution Gas System Connection (Optional)
PRV
MV
DGC
MAN
FME, FR
NIP
DGC
Dilution gas connection
FME
Flow meter
FR
Flow regulator
MAN
Manometer
MV
Solenoid valve
NIP
Nitrogen panel
PRV
Pressure regulating valve
• Connect the dilution gas connection (DGC) to the gas supply.
Connection size:
– G1/4, ISO 228-1
• Electrically connect the solenoid valve (MV), see
.
• Make sure that the gas complies with the following requirements:
Gas type
Dry nitrogen
Gas temperature
°C
0 ... 60
Maximum gas pressure
bar
13
Recommended pressure setting at the
pressure regulating valve (PRV)
bar
2.5
Filtration
µm
5
Recommended flow rate
SLM*
30
* standard litre per minute