Installation | 5
0870567092_NC0630C_WCV_A0006_IM_en
15 / 40
5.2.6 Purge Gas System Connection (Optional)
PRV
MV
PGC
MAN
FME, FR
INF
NIP
PGC
Purge gas connection
FME
Flow meter
FR
Flow regulator
INF
Inlet flange
MAN
Manometer
MV
Solenoid valve
NIP
Nitrogen panel
PRV
Pressure regulating valve
• Connect the purge gas connection to the gas supply.
Connection size:
– G1/4, ISO 228-1
• Electrically connect the solenoid valve (MV), see
.
• Make sure that the gas complies with the following requirements:
Gas type
Dry nitrogen
Gas temperature
°C
0 ... 60
Maximum gas pressure
bar
13
Recommended pressure setting at the
pressure regulating valve (PRV)
bar
2.5
Filtration
µm
5
Recommended flow rate
SLM*
≥
100
* standard litre per minute
5.3 Filling Oil
NOTICE
Use of an inappropriate oil.
Risk of premature failure!
Loss of efficiency!
• Only use an oil type which has previously been approved and recommended by
Busch.
Summary of Contents for COBRA NC 0600 C
Page 38: ...Note...
Page 39: ...Note...