Installation | 5
0870567092_NC0630C_WCV_A0006_IM_en
19 / 40
In case of a machine delivery without motor:
• Fit the second coupling hub on the motor shaft (separately delivered).
• Axially adjust the hub in such a way until value "E" is reached.
• When the coupling adjustment is done, lock the coupling hub by tightening the
radial screw.
• Mount the motor on the machine by including the coupling spider.
For further coupling information, go to
manual of the ROTEX
®
coupling.
5.7 Electrical Connection
DANGER
Live wires.
Risk of electrical shock.
• Electrical installation work must only be executed by qualified personnel.
• Make sure that the power supply for the motor is compatible with the data on the
nameplate of the motor.
• The electrical installation must comply with applicable national and international
standards.
• Provide a lockable disconnect switch on the power line so that the machine is com-
pletely secured during maintenance tasks.
• Provide an overload protection according to EN 60204-1 for the motor.
• Make sure that the motor of the machine will not be affected by electric or electro-
magnetic disturbance from the mains; if necessary seek advice from Busch.
• Connect the protective earth conductor.
• Electrically connect the motor.
NOTICE
The admissible motor nominal speed exceeds the recommendation.
Risk of damage to the machine!
• Check the admissible
motor nominal speed (n
max
) on the nameplate of the machine
(NP).
• Make sure to comply with it.
to get more information.
NOTICE
The motor frequency is below 20 Hz.
Risk of damage to the machine!
• The motor nominal speed must always be higher than 1200 min
-1
(20 Hz).
Summary of Contents for COBRA NC 0600 C
Page 38: ...Note...
Page 39: ...Note...