3 | Transport
6 / 28
0870549537_NC2000B_VR_A0004_IM_en
If a resistance thermometer is necessary to monitor the exhaust gas temperature, it may
be installed in either the exhaust outlet flange of the pump or in a suitable prepared ex-
haust spool piece at a distance of < 100 mm from the pump outlet.
The machine must be stopped either when the cooling liquid temperature or when the
exhaust gas temperature reaches the trip value, see Wiring Diagram Resistance Thermo-
meter.
2.6 P&ID "Piping and Instrumentation Diagram"
IN
OUT
CLI
INJ
CLO
0101
TSA+
M
CPL
MOT
0102
TSA+
= optional
CLI
Cooling liquid inlet connection
CLO
Cooling liquid outlet connection
CPL
Coupling
IN
Suction connection
INJ
Injection point
MOT
Motor
OUT
Discharge connection
TSA
Resistance thermometer
3
Transport
WARNING
Suspended load.
Risk of severe injury!
• Do not walk, stand or work under suspended loads.
WARNING
Lifting the machine using the motor eye bolt.
Risk of severe injury!
• Do not lift the machine using the eye bolt fitted to the motor. Only lift the machine as
shown.
NOTICE
In case the machine is already filled with oil.
Tilting a machine that is already filled with oil can cause large quantities of oil to in-
gress into the cylinder.
• Drain the oil prior to every transport or always horizontally transport the machine.