162
T-Modell - 17/18 - Ausgabe 09/17 - 2891569 - BUE-0029-19EN
Appliances
9
Switching off:
Press the On/Off button (Fig. 207,2). The lighting can continue to be oper-
ated.
Operation and display on
the unit
Certain functions can be operated directly on the unit.
Air distribution adjustment:
Set the small adjustment wheel and sliding regulator for stepless air distri-
bution as desired.
Switching on/off manually:
Press the micro button (e.g. with a ballpoint pen if the remote control is not
in reach).
Manual mode
In the manual mode, the cooling, heater, and air circulation can be set sepa-
rately on the remote control.
Switching on the cooling:
Press the On/Off button (Fig. 207,2).
Press the mode selection button (Fig. 207,6) until the cooling symbol
appears in the display (Fig. 207,1).
Use the "+" and "–" buttons (Fig. 207,3) to set the desired temperature.
Use the " " selection button (Fig. 207,5) to set the desired fan level.
When the room temperature set on the remote control is reached, the com-
pressor switches itself off and the blue LED in the IR receiver goes out. The
circulation fan continues to run.
When the room temperature rises above the set temperature, the unit auto-
matically switches itself back to cooling mode.
Switching on the heater:
Press the On/Off button (Fig. 207,2).
Press the mode selection button (Fig. 207,6) until the heating symbol
appears in the display (Fig. 207,1).
Use the "+" and "–" buttons (Fig. 207,3) to set the desired temperature.
Use the " " selection button (Fig. 207,5) to set the desired fan level.
Fig. 208 Function display and air distri-
bution (air conditioning unit)
1 Air distribution right/left
2 Air distribution ceiling/floor
3 IR receiver, function display, manual
on/off
4 Air distribution front/rear
Status LED
Signification
Function display
Blue LED flashes
Compressor starts up (cooling mode)
Blue LED lights up
Cooling operation
Yellow LED flashes
Compressor starts up (heating mode)
Yellow LED lights up
Heating mode
Red LED flashes
Data is transferred
Red LED lights up
Fault
Summary of Contents for Ixeo Time IT 590
Page 2: ...T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Instruction manual ...
Page 10: ...10 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Introduction 1 ...
Page 56: ...56 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Pitching the motorhome 5 ...
Page 118: ...118 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Gas system 7 ...
Page 184: ...184 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Appliances 9 ...
Page 248: ...248 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Special equipment 15 ...
Page 262: ...262 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Helpful notes 17 ...