22
SmartSource Advantage
User's Manual
3. Tilt the scanner slightly on its back side to locate the feed roller assembly. Push it
up a bit at the bottom and then hold both sides of it to pull it out carefully from its
compartment.
4. Insert the new feed roller assembly into its
compartment;
a) Snap the notches on the two sides
of the feed roller assembly onto the
shafts, located on the two sides of
the compartment.
b) Finally, push down the feed roller
assembly flat into its compartment.
5. Put the roller cover back and tighten
the screws to lock the roller cover at the
bottom of the scanner.
a
b
Note:
•
The recommended replacement point for your feed roller assembly is after scanning
approximately 30,000 sheets through the feeder.
•