background image

Lifetime Limited Warranty

Burntech® Fireplace Solutions

Burntech® Fireplace Solutions, Inc. warrants all Burntech® Fireplaces to be free from defects in materials that adversely affect fireplace 

performance for the lifetime of the product from the date of purchase, subject to the terms and conditions of this limited warranty. Burntech® 

Fireplace Solutions does not warrant accessory chimney, outside air ducts and devices not manufactured by Burntech® Fireplace Solutions.

This warranty covers only products manufactured by Burntech® Fireplace Solutions, specifically the modular masonry fireplace, and 

NO WARRANTY, EXPRESS OR IMPLIED, EXTENDS TO ANY OF THE HARDWARE, FOUNDATION, VENTING, DUCTS, 

OR ACCESSORIES. THIS WARRANTY DOES NOT COVER DRAFTING, SMOKING, OR SOOTING OF THE FIREPLACE 

SYSTEM

.  Factors beyond the manufacturer’s control affect drafting, smoking, and sooting and Burntech® Fireplace Solutions cannot 

guarantee these aspects of performance.

Coverage under this warranty is subject to the following conditions and exclusions:

This warranty is null and void when the fireplaces are not installed pursuant to the installation instructions provided by Burntech® 

Fireplace Solutions or local building codes have not been followed completely.
Glass is warranted against thermal breakage only and only on models that are manufactured by Burntech® Fireplace Solutions with a glass 

front. On Direct Vent models the safety glass or safety screen must be kept in front of this glass when fireplace is in use.

 

Safety screen must be used on all models when in use.
This warranty does not apply to any component or part that shows evidence of misuse, abuse, improper installation, accident or lack of 

regular maintenance.  Burntech® Fireplace Solutions is not responsible for misuse or mishandling of component parts.
This warranty does not apply to any damage sustained to the appliance while in transit.

Neither Burntech® Fireplace Solutions, nor any affiliate thereof, is responsible for any labor costs or indirect costs incurred for the 

replacement of defective components.  Any covered component that, in our judgment, is defective shall be repaired, replaced or refunded 

at Burntech® Fireplace Solutions’s option.

Nothing in this warranty makes Burntech® Fireplace Solutions, or any affiliate thereof, liable in any respect for any injury or damage to 

the building or structure in which the fireplace has been installed or to the persons or property therein arising out of the use, misuse, or 

installation of properly manufactured Burntech® Fireplace Solutions products.

The fireplace must be used in accordance with operating instructions. The grate or andirons must be installed when using the fireplace. 

NEITHER Burntech® Fireplace Solutions, NOR ANY AFFILIATE THEREOF, SHALL BE HELD LIABLE FOR ANY INCIDENTAL OR 

CONSEQUENTIAL DAMAGES OR EXPENSES ARISING OUT OF THE USE OF THE FIREPLACE. ALL SUCH DAMAGES AND 

EXPENSES ARE HEREBY EXCLUDED. Some states do not allow the exclusion or limitation of incidental or consequential damages, so 

the above limitation or exclusion may not apply to you.

If a component is found to be defective under the terms of this warranty the party this warranty is extended shall, notify Burntech® Fireplace 

Solutions,

 

6520 Platt Ave #577, West Hills, CA 91307 in writing, by registered mail, within thirty (30) days following the discovery of the 

defect within the lifetime warranty period. The letter shall include proof of purchase and state the (1) date of purchase, model number and 

serial number ; (2) place of purchase; (3) address of installation; (4) name, address and phone number of the homeowner; and (5) a brief 

description of the defect.

This warranty applies only to those fireplaces installed in the continental United States, Alaska and Canada. If any part of this warranty is 

found to be unenforceable, the remaining parts shall remain in force and effect.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, TERMS OR CONDITIONS, 

EXPRESS OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW.  Burntech® Fireplace Solutions HEREBY DISCLAIMS ALL 

GUARANTEES AND WARRANTIES, EXPRESS OR IMPLIED, BEYOND THE WARRANTIES SET FORTH HEREIN, INCLUDING 

BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not 

allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

Burntech® Fireplace Solutions

6520 Platt Ave #577, West Hills, CA 91307

Main: (818)564-4253,  Fax: (818) 564-4232

Revised 12/05/2012 

WWW.BURNTECH.COM 


Summary of Contents for GBVS 39

Page 1: ...50 standard Solid fuels shall not be burned in this fireplace This appliance must be vented vertically through the roof This appliance is not for installation in manufactured or mobile homes The installation including provisions for combustion ventilation air and required minimum permanent vent opening must conform with the National Fuel Gas Code ANSI Z223 1 NFPA 54 and applicable local building c...

Page 2: ...THIS PAGE INTENTIONALLY LEFT BLANK ...

Page 3: ...TYPE DO NOT REMOVE THIS LABEL See Burntech Installation Operating Instructions for this model Contact local building officials about restrictions and installation specifications in your area THIS FIREPLACE IS DESIGNED FOR USE ONLY WITH THE ANSI Z21 50 DECORATIVE GAS LOGS AND BURNER TESTED AND APPROVED FOR THIS FIREPLACE Consult instructions included with this firebox for further information WARNIN...

Page 4: ...mponents Warning Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury Figure 1 1 2 4 5 7 8 9 10 16 15 14 12 6 3 3A 7 8 11 17 10 18 19 ...

Page 5: ... DESCRIPTION QTY 1 TFS39 1 TFS44 1 TFS49 1 HEARTH Left or Right 2 2 TFS39 2 TFS44 2 TFS49 2 REAR WALL 3 3 TFS39 3 TFS44 3 TFS49 3 SIDE WALL 7 3A TFS39 3A TFS44 3A TFS49 3A SIDE WALL with 4 opening for Air Kit 1 4 TFS39 4 TFS44 4 TFS49 4 SMOKE SHELF Downdraft Diverter 1 5 TFS39 5 TFS44 5 TFS49 5 DOME REAR LOWER 1 6 TFS39 6 TFS44 6 TFS49 6 LINTEL 1 7 TFS39 7 TFS44 7 TFS49 7 DOME SIDE LOWER 2 8 TFS39...

Page 6: ...ment parts and accessories as listed in these parts lists Before beginning installation be sure the burner system is complete by comparing its contents with this Parts List Parts may differ depending upon the size of the set purchased Be sure you know the model number and size of your set when ordering replacement or optional parts and accessories Burner Log Kit and remote are sold seperately WARN...

Page 7: ... illustrations in this manual are for general reference only Do not scale drawings Actual design elements will vary from case to case Pay attention to specified minimum clearances to combustibles WARNING Under no circumstances should you allow children to remain unattended while a fire is burning in the fireplace Be sure to keep all objects furniture drapes rugs etc at least 48 48 inches away from...

Page 8: ... accessories Use of other controls parts and accessories which are not designed for use with Burntech gas fireplaces is prohibited and will void all warranties certifications listings and building code approvals and may cause property damage personal injury or loss of life The burner included with this gas fireplace is non convertible and only meant to be used with the gas listed on the rating pla...

Page 9: ...ading these procedures will save you time and at the most it will prevent any malfunction that could result in property damage or serious injury Do not start the installation until you have checked out all the local regional state and national rulings laws and codes as they apply to fireplaces and fireplace installations Every community is different so do not assume that because you know the requi...

Page 10: ...the addition of floor joists to align with the anchor brackets allows the brackets to be directly connected to the floor joists Note that additional floor joists may be required to support the weight of the firebox and chimney Where the floor joists run parallel to the front of the firebox anchorage can be accomplished in like manner as shown in Figure 6 using blocking between the floor joist For ...

Page 11: ... at time of installation and used under dry conditions the deflection resulting from L 0 5D is permitted to be substituted for the deflection resulting from L D Note that Burntech cannot accept responsibility for structural floor support details All drawings are presented as mere illustrations to indicate the presence of the underlying floor system It is the responsibility of the general contracto...

Page 12: ... washers GBVS 44 49 Eight 8 pieces 3 8 rebar x 36 long included with unit Eight 8 ea All thread x 12 long with nuts and washers ALL UNITS Three 3 90 lb bags of ready mix concrete with 1 4 or smaller aggregate SURFACE CRACKS The Burntech fireplaces are manufactured using high quality materials During the drying process surface cracking may occur These small cracks under 1 16 will not affect the fir...

Page 13: ...flatness level if necessary Figure 13 1 2 away from edges 1 2 mortar bead typical Hearth section shown prepared for Right Side position Apply mortar bead to all mating surfaces Apply mortar to the remaining Hearth except this time apply beading on surface to be facing floor as shown in Figure 14 1 2 3 4 5 Figure 14 Hearth shown prepared for Left Side position Before installing side walls confirm p...

Page 14: ...eveled face lines up with the inward angles of the lintel sides Resulting top surfaces should be level Figure 20 Lower Dome Sides Rating Plate faces inside Verify that the smoke dome side front and rear walls are aligning correctly and that the surfaces are smooth and uniform Make sure connections are covered with an adequate amount of mortar Remember that you have the option of using shims but th...

Page 15: ...25 Fireplace Finishes Combustible Trim Clearances Mantel and Mantel Shelf Clearances As with any radiant heat fireplaces all Burntech Fireplaces must comply with building code safety clearances per units that have openings of 6 sq ft six square feet or greater You must keep combustibles such as trim 8 away from the firebox opening for mantel clearances see Figure 26 Combustible material Figure 26 ...

Page 16: ... in an accident or malfunction If instructions are not followed the warranty on the product will become null and void 3 1 2 3 4 5 Note that the most important aspect of the installation is the maintenance of minimum required clearances to combustible materials Those specific installation requirements must be followed with great precision as you are dealing with the potential of fire hazard if the ...

Page 17: ... 1 One elbow begins the installation procedure and the second elbow is used to finish off each section In all likelihood a 30 degreeoffsetelbowwillprobablybethefirsthardwareusedoff the top of the anchor plate damper Note Under no circumstances should you use an offset elbow in place of a return elbow They have distinct purposes in the configuration of the offset installation and they cannot be int...

Page 18: ...clination Multiple offsets are permitted if they do not exceed a 45 inclination The total lengths of the two offsets are not required to meet the 75 allowable rule Figure 2 Example 3 Shows a single offset at 45 of inclination and therefore the lateral length at 10 ft of offset does not have to meet the 75 rule In each case the offsets must be supported and firestops must be positioned wherever the...

Page 19: ...are scheduled to install the round top termination unit or any of the flashings or flues that will be exposed to outside weather conditions Venting terminals shall not be recessed into walls or siding This appliance when installed must be electrically grounded in accordance with local codes and in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical ...

Page 20: ...tch sensor pointed toward the room out of the fireplace Use six 6 drywalls screws to fasten it in place on the front most part of the firebox ceiling as shown through the six 6 pre drilled holes Attach the trim plates to the left and right side of the baffle with the sheet metal screws so that the edges are flush with the firebrick Important This baffle assembly and only this one supplied with the...

Page 21: ... SOAPY WATER SOLUTION IF A LEAK IS DETECTED TIGHTEN CONNECTIONS AND TEST AGAIN NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS Insert a one way screw into the hole in the front of each bracket and tighten with a long min 12 screw driver until contactismadewiththegratelegandthegrateispermanently locked in place see Figure 23 IMPORTANT Once installed the burner cannot be removed Fill in the holes you...

Page 22: ...nd the heat chambers facing the back of the fireplace Figure 35 Place the front log on the grate in front of the top burner pipe with the flat down and the heat chambers toward the burner pipe and the log as far forward as possible while keeping the back parallel with the burner pipe Figure 36 Place top logs across the front and back logs in the order and positions shown in Figure 40 1 2 3 WARNING...

Page 23: ... the four 4 screws above and below the control panel face then pull the control panel out far enough to expose the test ports on the valve Figure 41 Unscrew the port marked IN part way and test CAUTION Do not kink the flex connectors coming from the valve while accessing it Figure 42 Lighting the Pilot Note Pilot flame should encircle top of electrodes See instructions cover for example of proper ...

Page 24: ...lts a Check with a millivolt meter Should be 250 millivolts or more b Pilot flame making a blowing sound b Pilot needs adjusting see Checking and Adjusting the Pilot on page 22 c Generator wire leads attached to the wrong terminals on the valve c Connect leads per wiring diagram previous page d Defective thermo magnetic safety in valve d Replace valve 2 Pilot Burning No Gas to Burner a Safety valv...

Page 25: ...oncrete slab The concrete strength and durability shall comply with Sections 1903 1904 and 1905 of the International Building Code IBC TABLE R402 2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE MINIMUM SPECIFIED COMPRESSIVE STRENGTH a f c Weathering Potential b TYPE OR LOCATION OF CONCRETE CONSTRUCTION Negligible Moderate Severe Basement walls foundations and other concrete not exposed to the...

Page 26: ...ely b Lines defining areas are approximate only Local conditions may be more or less severe than indicated by region classification A severe classification is where weather conditions result in significant snowfall combined with extended periods during which there is little or no natural thawing causing deicing salts to be used extensively ...

Page 27: ...nded at Burntech Fireplace Solutions s option Nothing in this warranty makes Burntech Fireplace Solutions or any affiliate thereof liable in any respect for any injury or damage to the building or structure in which the fireplace has been installed or to the persons or property therein arising out of the use misuse or installation of properly manufactured Burntech Fireplace Solutions products The ...

Reviews: