Burnham V9 Series Manual Download Page 8

V9 Series Ratings 

& equipment Listing

8

Burnham Commercial - Lancaster, PA

 

www.burnhamcommercial.com

PL81401291000-10/10-4Ms

1.  Suffix “S” indicates steam boiler, “W” indicates water boiler. Suffix “G” indicates gas-fired, “O” indicates oil fired and “GO” indicates combination 

 

  gas/oil fired.

2.  Boiler ratings are based on 12.5% CO2 on oil; 9.7% CO2 on gas, and .10 in. water column pressure at boiler flue outlet.

 

3.  I=B=R net ratings shown are based on piping and pick up allowances which vary from 1.333 to 1.289 for steam and 1.15 for water. Consult manufacturer for 

 

  installations having unusual piping and pick up requirements, such as intermittent system operation, extensive piping systems, etc.

4.  The I=B=R burner capacity in GPH is based on oil having a heat value of 140,000 BTU per gallon.
Ratings shown above apply to altitudes up to 1000 feet on oil and 2000 feet on gas. For altitudes above those indicated, the ratings should be reduced at the rate 
of 4% for each 1000 feet above above sea level.

nOTe: 

 

Maximum allowable working pressure (MAWP):

   

Steam: 15 PSI 

   

Water – USA: 80 PSI (standard relief valve provided is 50 PSI) (30 PSI and 80 PSI relief valve optional)

   

Water – Canada: 45 PSI (standard relief valve provided is 45 PSI) (30 PSI relief valve optional)

STAnDARD eQUIpMenT

ALL BOILeRS:

 Sections unassembled, flush insulated jacket, burner mounting plate, burner adapter plate, 

rear flue outlet damper

 (top outlet optional), flue 

canopy, rear observation port cover, target wall (V-903A), and miscellaneous plugs, bushing and fittings, L4006B (low fire hold aquastat).

STeAM TRIM:

 15 PSI safety valve, L404FA pressuretrol, gauge glass assembly, steam gauge

WATeR TRIM:

 50 PSI safety relief valve, L4006A high limit, pressure/temperature gauge

OIL BOILeRS:

 Flange mounted flame retention oil burner furnished with 2 stage fuel unit, primary control and dual oil valves

GAS BOILeRS:

 Flange mounted gas burner with standard controls meeting the latest UL requirements, dual gas valves, gas-electric ignition with proven gas pilot, 

flame rod on JR burner, ultra violet flame detector on others, electronic programming controls and components are factory wired in a burner mounted control panel.

GAS/OIL BURneRS:

 Flange mounted combination gas/oil burner with standard controls meeting latest UL requirements, manually operated fuel transfer switch for 

dual fuel changeover, dual gas valves and oil valves, electric ignition with proven gas pilot on both fuels (direct spark ignition of oil is optional), ultra-violet flame 
detector, electronic programming controls and components are factory wired in a burner mounted control panel.

OpTIOnAL eQUIpMenT

Assembled sections; completely packaged (includes manual reset 
high limit and manual reset low water cutoff); packaged and fire-
tested; 

top outlet flue damper

; tankless heaters; side inspection 

tappings with brass plugs; 30 PSI and 80 PSI safety relief valves 

(water); combustion and hydronic controls to meet special 

applications including F.M., I.R.I., and ASME CSD-1.

BOILeR 

MODeL (1)

BOILeR H.p.

GROSS 

OUTpUT 
MBH (2)

neT I=B=R RATInGS (2) (3)

BURneR InpUT

neT 

FIReBOX 
VOLUMe 

(CU. FT)

pReSSURe 

In FIReBOX 

(In. WTR. 

COLUMn)

I=B=R VenT 

DIA. (In.)

STeAM

WATeR 

MBH

OIL

(GpH) (4)

GAS

(MBH)

MBH

SQ. FT.

V-903A
V-904A
V-905A
V-906A
V-907A
V-908A
V-909A
V-910A
V-911A
V-912A

10.3

14.4
19.3
24.1
28.6
33.2

40.1

45.6
51.2
56.8

347
483
646

808

959

1110

1342
1528
1714

1900

260

362
485

606

719
833

1014

1168
1323
1474

1083
1508
2021

2525
2996
3471
4225
4867
5513
6142

302
420

562

703

834
965

1167
1329

1490

1652

3.1
4.2
5.6

7.0

8.3
9.6

11.6
13.2
14.8
16.4

447

606
808

1010

1198
1386
1674

1905

2136
2367

3.2
4.8
6.4
7.9
9.5

11.0

12.6
14.2
15.7
17.3

.33
.38
.31
.38
.36
.35
.35

.40

.45
.49

7
7
8
8
8

10
10
10

12
12

BOILeR 
MODeL

nUMBeR OF V9-2 TAnKLeSS* 

HeATeRS InSTALLeD

1

2

3

4

V-903A

6.75

Ñ

Ñ

Ñ

V-904A

7.5

Ñ

Ñ

Ñ

V-905A

7.5

Ñ

Ñ

Ñ

V-906A

7.5

15

Ñ

Ñ

V-907A

7.5

15

Ñ

Ñ

V-908A

7.5

15

Ñ

Ñ

V-909A

7.5

15

22.5

Ñ

V-910A

7.5

15

22.5

Ñ

V-911A

7.5

15

22.5

Ñ

V-912A

7.5

15

22.5

30.0

TAnKLeSS 
HeATeR 
RATInGS* 
(Water and 
Steam)

* Ratings are given in 

gallons per minute  

continuous draw of 

water heated from 

40°F to 140°F with 

200°F boiler water.

Phone: 

-888-791-3790

Summary of Contents for V9 Series

Page 1: ...or Steam Boiler 447 to 2367 MBH Input Oil Gas or Oil Gas Combination 30 50 or 80 PSI Cast Iron Sectional Design Water or Steam Top or Rear Venting Exclusive Optional SBC Boiler Control M aximizes Sys...

Page 2: ...gross output ratings from 347 to 1900 MBH the V9 Series fires gas oil or combination gas oil and is available equipped with either steam or water trim The product meets the energy efficiency requireme...

Page 3: ...ial America s Boiler Company has earned a reputation for quality and dependability Built for a variety of applications the V9 Series is right for your next job Individual Draw Rods with reinforced lug...

Page 4: ...tability Easily integrated into existing or new building management systems Simplified connections available to most building management systems through Modbus or standard 0 10 volt signals Uses sophi...

Page 5: ...JB G H V903A 3 18 1 4 12 1 9 1 8 1 7 8 9 3 4 8 20 7 8 8 23 1 4 8 20 1 8 908 1278 V904A 4 24 1 4 18 1 12 1 8 1 7 8 11 3 4 8 21 5 8 8 23 1 4 8 20 1 8 8 30 1194 1590 V905A 5 30 1 4 24 1 15 1 8 1 8 8 11 3...

Page 6: ...A V912A 2 2 2 2 1 2 2 1 2 2 1 2 3 3 3 4 1 1 2 1 1 2 1 1 2 1 1 2 2 2 2 2 1 2 2 1 2 2 1 2 2 2 2 2 1 2 2 1 2 2 1 2 3 3 3 4 1 1 2 1 1 2 1 1 2 1 1 2 2 2 2 2 1 2 2 1 2 2 1 2 3 2 3 STeAM BOILeR pIpInG nOTeS...

Page 7: ...URe InCHeS V903A V904A V905A V906A V907A V908A V909A V910A V911A V912A CG10 1S CG10 4S CG10 5S CG10 6S CG15 3S CG15 4S CG25 2S CG25 3S CG25 4S CG50 2S 1 3 1 3 1 3 1 3 1 2 1 2 3 4 3 4 3 4 2 3 3 3 7 4 7...

Page 8: ...gas valves gas electric ignition with proven gas pilot flame rod on JR burner ultra violet flame detector on others electronic programming controls and components are factory wired in a burner mounted...

Reviews: