Burnham V9 Series Manual Download Page 2

2

Installation & Service Flexibility

The cast iron sectional design of the V9 boiler makes it easy to 

maneuver through doorways and into the boiler room. In addi-
tion to being shipped as loose sections, the boiler is available 
with factory-assembled sections or as a completely packaged 

and fire-tested unit. Packaged units, fastened to a steel skid, 
are easily maneuvered through standard 36" x 80" doorways.

 

Hassle-free Section Assembly

 

V9 boiler sections have reinforced lugs that are used  

  to assemble the sections with individual draw rods   
  resulting in fast, strain-free assembly. 

 
 

 

The sections can be assembled using two common  

  toolsÑ a 3/4" drive ratchet with a 1-1/16" deep socket 
  and wrench.

 

The sections are surface ground to ensure

  smooth surface mating. An elastic sealant and fiberglass   
  rope are used on all section joints for a completely sealed   
  and pressure-tight assembly.

 

extensive Testing Methods

 

Each boiler section is hydrostatically tested at 2-1/2 times

  the rated working pressure at the foundry. Factory   

 

  assembled sections are tested at 1.5 times the rated   
  working pressure.

 

Rear or Top Venting

 

As a forced draft boiler, the V9

  provides optimum draft for controlled  
  efficiency, eliminating the need for  
  high chimneys or induced draft fans.  

  A unique feature of the V9 boiler is it 

  can be vented from the rear or the
  top. This enables easy chimney or  
  sidewall venting for maximum   
  installation flexibility.
  Top outlet venting saves floor space
  and reduces installation time and  
  materials.  A plugged tapping is   

 

  provided to take flue outlet pressure   
  readings.

Available in ten sizes with gross output ratings from 347 to 

1900 MBH, the V9 Series fires gas, oil or combination gas/oil 

and is available equipped with either steam or water trim. The 

product meets the energy efficiency requirements of ASHRAE 
90.1 with combustion efficiencies up to 86%.

Cast iron construction, ease of assembly, two venting options, 

and stringent testing methods make the V9 Series boiler by 

Burnham Commercial your commercial heating solution.

American-Made Cast Iron ConstructionÐ

BC25-HSi

Burnham CommercialÕ s unique 

BC25-HSi cast iron has an extremely 

high silicon content, making it 
stronger and more flexible. It offers 
better thermal shock resistance and 
greater heat transfer capabilities than 

other cast iron products. BC25-HSi's 

properties allow Burnham Commercial 
to maintain the highest level of quality 
from start to finish, and provide a 
product that is optimized for hydronic 
heating applications

.

 

Manufactured with Quality

 

Cast iron sections are poured at

  Burnham Foundry, LLC in Zanesville  
  Ohio. The foundry uses state-of    

  the-art technology and production  
  techniques which ensures the availability of high quality  
  boiler sections. 

 

Cast Iron nipple Difference

 

While gaskets used by other  

 

 

  manufacturers can break down
  from oils and contaminants, the

  V9's cast iron nipples remain 

  unaffected, ensuring long life and  

 

  eliminating costly repairs.

  The V9 section assembly includes precision machined 

cast  

  iron nipples that expand and contract along with the 
  sections they join, providing integrity to the entire 
  assembly.  Additionally, cast iron nipples resist boiler flue
  gases and petroleum based chemicals, including corrosion  
  inhibitors, pump lubricants and antifreeze. 

Your Commercial Heating Solution!

 

 

Cast Iron Commercial Water or Steam Boiler

V9

 Series

Summary of Contents for V9 Series

Page 1: ...or Steam Boiler 447 to 2367 MBH Input Oil Gas or Oil Gas Combination 30 50 or 80 PSI Cast Iron Sectional Design Water or Steam Top or Rear Venting Exclusive Optional SBC Boiler Control M aximizes Sys...

Page 2: ...gross output ratings from 347 to 1900 MBH the V9 Series fires gas oil or combination gas oil and is available equipped with either steam or water trim The product meets the energy efficiency requireme...

Page 3: ...ial America s Boiler Company has earned a reputation for quality and dependability Built for a variety of applications the V9 Series is right for your next job Individual Draw Rods with reinforced lug...

Page 4: ...tability Easily integrated into existing or new building management systems Simplified connections available to most building management systems through Modbus or standard 0 10 volt signals Uses sophi...

Page 5: ...JB G H V903A 3 18 1 4 12 1 9 1 8 1 7 8 9 3 4 8 20 7 8 8 23 1 4 8 20 1 8 908 1278 V904A 4 24 1 4 18 1 12 1 8 1 7 8 11 3 4 8 21 5 8 8 23 1 4 8 20 1 8 8 30 1194 1590 V905A 5 30 1 4 24 1 15 1 8 1 8 8 11 3...

Page 6: ...A V912A 2 2 2 2 1 2 2 1 2 2 1 2 3 3 3 4 1 1 2 1 1 2 1 1 2 1 1 2 2 2 2 2 1 2 2 1 2 2 1 2 2 2 2 2 1 2 2 1 2 2 1 2 3 3 3 4 1 1 2 1 1 2 1 1 2 1 1 2 2 2 2 2 1 2 2 1 2 2 1 2 3 2 3 STeAM BOILeR pIpInG nOTeS...

Page 7: ...URe InCHeS V903A V904A V905A V906A V907A V908A V909A V910A V911A V912A CG10 1S CG10 4S CG10 5S CG10 6S CG15 3S CG15 4S CG25 2S CG25 3S CG25 4S CG50 2S 1 3 1 3 1 3 1 3 1 2 1 2 3 4 3 4 3 4 2 3 3 3 7 4 7...

Page 8: ...gas valves gas electric ignition with proven gas pilot flame rod on JR burner ultra violet flame detector on others electronic programming controls and components are factory wired in a burner mounted...