![Burnham V9 Series Manual Download Page 7](http://html1.mh-extra.com/html/burnham/v9-series/v9-series_manual_2832995007.webp)
7
V9 Series Burner Schedule
OIL BURneRS
Standard Burner Motor Voltage:
Beckett
– CF500, CF800, CF1400, and CF2300A are 120/60/1. CF2500A is 240/60/1.
Carlin
– 301CRD and 702CRD are 120/60/1. 801CRD is 240/60/1.
power Flame
– C1-OS is 120/60/1. C2-OAS and C2-OB are 240/60/1.
Webster
– JB1O-02, JB1O-03, and JB1O-05 are 120/60/1. JB1O-07 is 240/60/1.
GAS BURneRS*
Standard Motor Voltage:
Beckett
– V903 through V911 120/60/1, V912 240/60/1
power Flame C Series
– C1-G-10, C1-G-12, C2-G-15 are 120/60/1. C2-G-20A and C2-G-20B are 240/60/1.
power Flame JR Series
– All burners are 120/60/1.
Webster
–JB1G-02, JB1G-03 and JB1G-05 are 120/60/1. JB1G-07 is 240/60/1.
GAS/OIL BURneRS
Standard Burner Motor:
power Flame
– C1-GO-10 and C1-GO-12 are 120/60/1. C2-GO-15, C2-GO-20A and C2-GO-20B are 240/60/1.
Webster
– JB1C-02, JB1C-03, and JB1C-05 are 120/60/1. JB1C-07 and JB1C-10 are 240/60/1.
BOILeR
MODeL
BeCKeTT
CARLIn
pOWeR FLAMe
WeBSTeR
BURneR
MODeL
H.p.
BURneR
MODeL
H.p.
BURneR
MODeL
H.p.
BURneR
MODeL
H.p.
V903A
V904A
V905A
V906A
V907A
V908A
V909A
V910A
V911A
V912A
CF500
CF800
CF800
CF1400
CF1400
CF1400
CF2300A
CF2300A
CF2500A
CF2500A
1/3
1/3
1/3
1/2
1/2
1/2
3/4
3/4
2
2
301CRD
301CRD
301CRD
702CRD
702CRD
702CRD
801CRD
801CRD
801CRD
801CRD-B
1/4
1/4
1/4
1/2
1/2
1/2
3/4
3/4
3/4
1-1/2
Ñ
C1-OS
C1-OS
C1-OS
C1-OS
C2-OAS
C2-OAS
C2-OAS
C2-OB
C2-OB
Ñ
1/3
1/3
1/2
1/2
3/4
3/4
3/4
1-1/2
1-1/2
Ñ
Ñ
JB1O-02
JB1O-03
JB1O-03
JB1O-03
JB1O-05
JB1O-05
JB1O-07
JB1O-07
Ñ
Ñ
1/4
1/3
1/3
1/3
1/2
1/2
3/4
3/4
BOILeR
MODeL
BeCKeTT
pOWeR FLAMe*
C SeRIeS
pOWeR FLAMe
JR SeRIeS
WeBSTeR
BURneR
MODeL
H.p.
MIn. GAS
pReSSURe
InCHeS
BURneR
MODeL
H.p.
BURneR
MODeL
H.p.
MIn. GAS
pReSSURe
InCHeS
BURneR
MODeL
MIn. GAS
pReSSURe
InCHeS
V903A
V904A
V905A
V906A
V907A
V908A
V909A
V910A
V911A
V912A
CG10-1S
CG10-4S
CG10-5S
CG10-6S
CG15-3S
CG15-4S
CG25-2S
CG25-3S
CG25-4S
CG50-2S
1/3
1/3
1/3
1/3
1/2
1/2
3/4
3/4
3/4
2
3.3
3.7
4.7
5.5
5.4
6.2
4.7
5.0
4.9
3.9
Ñ
C1-G-10
C1-G-10
C1-G-12
C1-G-12
C2-G-15
C2-G-20A
C2-G-20A
C2-G-20B
C2-G-20B
Ñ
1/3
1/3
1/2
1/2
1/2
3/4
3/4
1
1
JR15A-10
JR30A-10
JR30A-12
JR30A-12
JR50A-15
JR50A-15
JR50A-15
Ñ
Ñ
Ñ
1/4
1/3
1/3
1/3
1/3
1/3
1/3
Ñ
Ñ
Ñ
4.0
4.2
5.9
4.3
5.4
4.4
5.0
Ñ
Ñ
Ñ
Ñ
JB1G-02
JB1G-02
JB1G-02
JB1G-02
JB1G-03
JB1G-05
JB1G-05
JB1G-07
JB1G-07
Ñ
5.0
8.0
5.0
6.0
8.0
6.0
6.0
7.0
9.0
BOILeR
MODeL
pOWeR FLAMe - C SeRIeS
WeBSTeR**
BURneR
MODeL
H.p.
InLeT GAS
COnneCTIOn
InCHeS
MIn. GAS
pReSSURe
InCHeS
BURneR
MODeL
H.p.
InLeT GAS
COnneCTIOn
InCHeS
V904A
V905A
V906A
V907A
V908A
V909A
V910A
V911A
V912A
C1-GO-10
C1-GO-10
C1-GO-12
C1-GO-12
C2-GO-15
C2-GO-20A
C2-GO-20A
C2-GO-20B
C2-GO-20B
1/3
1/3
1/2
1/2
3/4
1
1
1-1/2
1-1/2
1
1
1
1
1
1-1/4
1-1/4
1-1/4
1-1/2
4.4
4.4
4.8
5.2
6.4
4.9
5.2
5.4
5.0
Ñ
JB1C-02
JB1C-03
JB1C-03
JB1C-05
JB1C-05
JB1C-05
JB1C-07
JB1C-10
Ñ
1/4
1/3
1/3
1/2
1/2
1/2
3/4
1
Ñ
1-1/4
1-1/4
1-1/2
1-1/2
1-1/2
1-1/2
2
2
V9 Series Burners
Optional Motor Voltage:
Most models have 208-240 or 480 volts/3phase available
at additional cost as an option. Consult your Burnham
Commercial sales representative.
Optional Burner Motor Voltage:
Most models have 208-240 or 480 volts/3phase
available at additional cost as an option. Consult your
Burnham Commercial sales representative.
* For gas connection size on Gordon-Piatt, Webster and
Power Flame C burners and minimum gas pressure
for C burner see gas/oil burner chart.
Optional Burner Motor Voltage:
Most models have 208-240 or 480 volts/
3phase available at additional cost as an
option. Consult your Burnham Commercial
sales representative.
** For minimum gas pressure
requirements, see gas burner chart.
OIL BURneRS