Burnham V9 Series Manual Download Page 7

7

V9 Series Burner Schedule

OIL BURneRS

Standard Burner Motor Voltage: 

Beckett

 – CF500, CF800, CF1400, and CF2300A are 120/60/1. CF2500A is 240/60/1.

Carlin

 – 301CRD and 702CRD are 120/60/1. 801CRD is 240/60/1. 

power Flame

 – C1-OS is 120/60/1. C2-OAS and C2-OB are 240/60/1. 

Webster

 – JB1O-02, JB1O-03, and JB1O-05 are 120/60/1. JB1O-07 is 240/60/1. 

GAS BURneRS*

Standard Motor Voltage: 

Beckett

 – V903 through V911 120/60/1, V912 240/60/1

power Flame C Series 

– C1-G-10, C1-G-12, C2-G-15 are 120/60/1. C2-G-20A and C2-G-20B are 240/60/1.

power Flame JR Series

 – All burners are 120/60/1.

Webster

 –JB1G-02, JB1G-03 and JB1G-05 are 120/60/1. JB1G-07 is 240/60/1.

GAS/OIL BURneRS

Standard Burner Motor: 

power Flame

 – C1-GO-10 and C1-GO-12 are 120/60/1. C2-GO-15, C2-GO-20A and C2-GO-20B are 240/60/1. 

Webster

 – JB1C-02, JB1C-03, and JB1C-05 are 120/60/1. JB1C-07 and JB1C-10 are 240/60/1.

BOILeR 
MODeL

BeCKeTT

CARLIn

pOWeR FLAMe

WeBSTeR

BURneR 

MODeL

H.p.

BURneR 

MODeL

H.p.

BURneR 

MODeL

H.p.

BURneR 

MODeL

H.p.

V903A
V904A
V905A
V906A
V907A
V908A
V909A
V910A
V911A
V912A

CF500
CF800
CF800

CF1400
CF1400
CF1400

CF2300A
CF2300A
CF2500A
CF2500A

1/3
1/3
1/3
1/2
1/2
1/2
3/4
3/4

2
2

301CRD
301CRD
301CRD
702CRD
702CRD
702CRD
801CRD
801CRD
801CRD

801CRD-B

1/4
1/4
1/4
1/2
1/2
1/2
3/4
3/4
3/4

1-1/2

Ñ

C1-OS
C1-OS
C1-OS
C1-OS

C2-OAS
C2-OAS
C2-OAS

C2-OB
C2-OB

Ñ

1/3
1/3
1/2
1/2
3/4
3/4
3/4

1-1/2
1-1/2

Ñ
Ñ

JB1O-02
JB1O-03
JB1O-03
JB1O-03
JB1O-05
JB1O-05
JB1O-07
JB1O-07

Ñ
Ñ

1/4
1/3
1/3
1/3
1/2
1/2
3/4
3/4

BOILeR 
MODeL

BeCKeTT

pOWeR FLAMe*

C SeRIeS

pOWeR FLAMe

JR SeRIeS

WeBSTeR

BURneR 

MODeL

H.p.

MIn. GAS 

pReSSURe 

InCHeS

BURneR 

MODeL

H.p.

BURneR 

MODeL

H.p.

MIn. GAS 

pReSSURe

InCHeS

BURneR 

MODeL

MIn. GAS 

pReSSURe

InCHeS

V903A
V904A
V905A
V906A
V907A
V908A
V909A
V910A
V911A
V912A

CG10-1S
CG10-4S
CG10-5S
CG10-6S
CG15-3S
CG15-4S
CG25-2S
CG25-3S
CG25-4S
CG50-2S

 1/3
 1/3
 1/3
 1/3
 1/2
 1/2
 3/4
 3/4
 3/4

2

3.3
3.7
4.7
5.5
5.4
6.2
4.7

5.0

4.9
3.9

Ñ

C1-G-10
C1-G-10
C1-G-12
C1-G-12
C2-G-15

C2-G-20A
C2-G-20A
C2-G-20B
C2-G-20B

Ñ

1/3
1/3
1/2
1/2
1/2
3/4
3/4

1
1

JR15A-10
JR30A-10
JR30A-12
JR30A-12
JR50A-15
JR50A-15
JR50A-15

Ñ
Ñ
Ñ

1/4
1/3
1/3
1/3
1/3
1/3
1/3

Ñ
Ñ
Ñ

4.0

4.2
5.9
4.3
5.4
4.4

5.0

Ñ
Ñ
Ñ

Ñ

JB1G-02
JB1G-02
JB1G-02
JB1G-02
JB1G-03
JB1G-05
JB1G-05
JB1G-07
JB1G-07

Ñ

5.0
8.0
5.0
6.0
8.0
6.0
6.0
7.0
9.0

BOILeR 
MODeL

pOWeR FLAMe - C SeRIeS

WeBSTeR**

BURneR 

MODeL

H.p.

InLeT GAS  

COnneCTIOn

InCHeS

MIn. GAS 

pReSSURe

InCHeS

BURneR 

MODeL

H.p.

InLeT GAS  

COnneCTIOn 

InCHeS

V904A
V905A
V906A
V907A
V908A
V909A
V910A
V911A
V912A

C1-GO-10
C1-GO-10
C1-GO-12
C1-GO-12
C2-GO-15

C2-GO-20A
C2-GO-20A
C2-GO-20B
C2-GO-20B

1/3
1/3
1/2
1/2
3/4

1
1

1-1/2
1-1/2

1
1
1
1
1

1-1/4
1-1/4
1-1/4
1-1/2

4.4
4.4
4.8
5.2
6.4
4.9
5.2
5.4

5.0

Ñ

JB1C-02
JB1C-03
JB1C-03
JB1C-05
JB1C-05
JB1C-05
JB1C-07
JB1C-10

Ñ

1/4
1/3
1/3
1/2
1/2
1/2
3/4

1

Ñ

1-1/4
1-1/4
1-1/2
1-1/2
1-1/2
1-1/2

2
2

V9 Series Burners

Optional Motor Voltage: 

Most models have 208-240 or 480 volts/3phase available 

at additional cost as an option. Consult your Burnham 

Commercial sales representative. 

Optional Burner Motor Voltage: 

Most models have 208-240 or 480 volts/3phase 

available at additional cost as an option. Consult your 

Burnham Commercial sales representative.

* For gas connection size on Gordon-Piatt, Webster and  

  Power Flame C burners and minimum gas pressure  

  for C burner see gas/oil burner chart. 

Optional Burner Motor Voltage:

Most models have 208-240 or 480 volts/

3phase available at additional cost as an 

option. Consult your Burnham Commercial 

sales representative. 

**  For minimum gas pressure  

 

  requirements, see gas burner chart. 

OIL BURneRS

Summary of Contents for V9 Series

Page 1: ...or Steam Boiler 447 to 2367 MBH Input Oil Gas or Oil Gas Combination 30 50 or 80 PSI Cast Iron Sectional Design Water or Steam Top or Rear Venting Exclusive Optional SBC Boiler Control M aximizes Sys...

Page 2: ...gross output ratings from 347 to 1900 MBH the V9 Series fires gas oil or combination gas oil and is available equipped with either steam or water trim The product meets the energy efficiency requireme...

Page 3: ...ial America s Boiler Company has earned a reputation for quality and dependability Built for a variety of applications the V9 Series is right for your next job Individual Draw Rods with reinforced lug...

Page 4: ...tability Easily integrated into existing or new building management systems Simplified connections available to most building management systems through Modbus or standard 0 10 volt signals Uses sophi...

Page 5: ...JB G H V903A 3 18 1 4 12 1 9 1 8 1 7 8 9 3 4 8 20 7 8 8 23 1 4 8 20 1 8 908 1278 V904A 4 24 1 4 18 1 12 1 8 1 7 8 11 3 4 8 21 5 8 8 23 1 4 8 20 1 8 8 30 1194 1590 V905A 5 30 1 4 24 1 15 1 8 1 8 8 11 3...

Page 6: ...A V912A 2 2 2 2 1 2 2 1 2 2 1 2 3 3 3 4 1 1 2 1 1 2 1 1 2 1 1 2 2 2 2 2 1 2 2 1 2 2 1 2 2 2 2 2 1 2 2 1 2 2 1 2 3 3 3 4 1 1 2 1 1 2 1 1 2 1 1 2 2 2 2 2 1 2 2 1 2 2 1 2 3 2 3 STeAM BOILeR pIpInG nOTeS...

Page 7: ...URe InCHeS V903A V904A V905A V906A V907A V908A V909A V910A V911A V912A CG10 1S CG10 4S CG10 5S CG10 6S CG15 3S CG15 4S CG25 2S CG25 3S CG25 4S CG50 2S 1 3 1 3 1 3 1 3 1 2 1 2 3 4 3 4 3 4 2 3 3 3 7 4 7...

Page 8: ...gas valves gas electric ignition with proven gas pilot flame rod on JR burner ultra violet flame detector on others electronic programming controls and components are factory wired in a burner mounted...

Reviews: