background image

9. 

Light the fire using the method in the instructions and ensure that the pilot lights consistently and 
the pilot flame envelopes the thermocouple evenly, it is located at the front on the right-hand side. 
The pilot should hold in 6-10 seconds.  Turn control to main burner, this should light smoothly 
within 10 seconds.  Ensure the valve gives adequate turn down and the thermostat bulb reduces 
the burner rate to off when heated. 
Locate thermostat bulb in a cool place off the appliance and preferably outside of any inglenooks, 
to ensure it is sensing room air temperature. 
 
Run the appliance for 10 minutes, ensuring burner flames settle evenly. 
 
The gas manifold pressures are factory pre-set using highly accurate equipment, and must not be 
altered.   
The catalyst is unlikely to need replacement during the life of the heater.  The appliance should be 
inspected before use and at least annually by an authorised service person.  More frequent cleaning 
may be required due to accumulation of lint and dust from carpeting etc. 
It is imperative that the control compartments, burners and circulating air passageways of the 
appliance be kept clean.  Replacement parts are available from your local dealer.   
 

18

 

Accessories

 

The range of accessories for this stove includes dummy flue kits, which simulate a real stovepipe 
and warming shelves. Consult your dealer or Burley for a full list of optional accessories and follow 
the instructions for their use. 
 
Using unapproved accessories could prove hazardous and will invalidate the warranty. 
 

User Instructions

 

Read the instructions before using this appliance. 
This appliance requires installation and annual servicing by a Gas Safe™ registered installer 
(formerly CORGI). 
Use only in a correctly sized and ventilated area. 
Any purpose provided ventilation should be checked regularly to ensure it is free from obstruction. 
Once the coals or logs have been positioned in accordance with the installation instructions, they 
must not be moved except for servicing. 
The surfaces of the appliance become very hot during use. 
Before cleaning or maintenance switch fire OFF and allow to 
cool. 
Do not attempt to touch or wipe clean the fire whilst hot, 
doing so could result in severe burns or damage to the 
paintwork. 
 

TO LIGHT THE HEATER 

There are 2 control knobs on the appliance. The left hand one (coloured red) controls On / Off and 
High / Low flame. The right hand one (coloured black) is the comfort level thermostat which turns 
the fire to pilot position once the desired temperature is reached. Some people prefer to retain a 
flame effect using the left hand knob to control its height whilst keeping the thermostat set on hot. 
Others prefer to use the fire purely as a heater in which case they will select a flame height then set 
the thermostat to a comfort level. In both cases if the room gets too hot, the thermostat will reduce 
the fire to pilot setting.  

 

If during use the pilot is alight but the main burner will not light, check the thermostat position and 
if necessary select a warmer setting.  

Control Knob 

T hermos tat 

Summary of Contents for G4220 - 9

Page 1: ...ances Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 756956 Fax 44 0 1572 724390 e mail info burley co uk web www burley co uk G4221InstUser G20 31 Issue MARCH 09 v 4 TO OBTAIN YOUR FIR...

Page 2: ...egory I2H I3P Supply Pressure 20mBar 37mBar Inlet Pressure 20mBar 37mBar Heat Input Net High 2 5kW 2 5kW 180g h Low 1 5kW 1 5kW 107g h Inlet Connection 8mm Compression 8mm Compression Injector Elbow 3...

Page 3: ...on the appliance is to prevent risk of fire or injury from burns and no part of it may be permanently removed It does not give full protection for young children the elderly or infirm Parts of the ap...

Page 4: ...n a floor can lead to discolouration and or drying out When a hearth is used the top surface can be wood but be aware that heat can discolour certain finishes over a period of time and can dry out poo...

Page 5: ...e met then the appliance should not be installed Consideration should be given to the requirements of other appliances working in the same room space If other flueless appliances such as cookers are i...

Page 6: ...he coal sits with the 4 coal shapes uppermost and coal profile facing you The feet on the front coal locate between the burner and tags in the burner tray Always secure the door closed after laying th...

Page 7: ...The left hand one coloured red controls On Off and High Low flame The right hand one coloured black is the comfort level thermostat which turns the fire to pilot position once the desired temperature...

Page 8: ...ommencing any servicing ensure that the gas is isolated and the appliance is cool Cleaning The casing should be wiped with a cloth dampened in soapy water The glass may be cleaned with any non abrasiv...

Page 9: ...for their use Using unapproved accessories could prove hazardous and will invalidate the warranty User Instructions Read the instructions before using this appliance This appliance requires installat...

Page 10: ...ry out the lighting procedure to re ignite Cleaning the fuel effect Switch the appliance OFF and allow to cool before commencing The fuels can be accessed by opening the hinged door on the appliance w...

Page 11: ...ured to BS7967 and the test must be carried out in accordance with BS5871 Pt 4 The catalytic converter needs heat to work therefore before you start testing the fire must have been lit and burning on...

Page 12: ...ult the relevant manufacturer Only use replacement catalyst supplied by Burley If you or the customer detects any odours from the fire please remember that the catalytic convertor is not an air filter...

Page 13: ...ant to take a gas rate test over a reasonable period of time so that the capacity of the meter is used On low Input appliances such as our flueless this is even more critical because uncertainties can...

Page 14: ...first year as with all gas products every gas appliances must be serviced every year The appliance has not been subject to misuse accident or repaired or fitted by anyone other than a Gas Safe regist...