background image

6. 

 
 

9  Fitting back coal 

Take the ceramic back block and place into position as shown. The coal shapes should be facing you 

and the base of the 
coal locates behind 
the tags on the 
burner. 
 
 
 
 
 
 
 
 
 
 

 
 

10  Fitting front Coal 

The front coal fits vertically between the burner and the front of the case as shown.  
The coal sits with the 4 coal shapes uppermost and coal profile facing you. The feet on the front 
coal locate between the burner and tags in the burner tray. 
 

 

 

 

 

 

 

 
 
 
 
 
 

 

 
 
 
 

 

Always secure the door closed after laying the fuel effects. 

 

Do not attempt to use any unit with broken or damaged glass. 

 

Do not use the fire with broken coals. 

 

Do not add any additional fuel elements to the fire. 

 

Do not use similar looking parts from other appliances,  

 

Use only genuine spare parts. 

 

Do not use the appliance for burning waste

 

 

Summary of Contents for G4220 - 9

Page 1: ...ances Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 756956 Fax 44 0 1572 724390 e mail info burley co uk web www burley co uk G4221InstUser G20 31 Issue MARCH 09 v 4 TO OBTAIN YOUR FIR...

Page 2: ...egory I2H I3P Supply Pressure 20mBar 37mBar Inlet Pressure 20mBar 37mBar Heat Input Net High 2 5kW 2 5kW 180g h Low 1 5kW 1 5kW 107g h Inlet Connection 8mm Compression 8mm Compression Injector Elbow 3...

Page 3: ...on the appliance is to prevent risk of fire or injury from burns and no part of it may be permanently removed It does not give full protection for young children the elderly or infirm Parts of the ap...

Page 4: ...n a floor can lead to discolouration and or drying out When a hearth is used the top surface can be wood but be aware that heat can discolour certain finishes over a period of time and can dry out poo...

Page 5: ...e met then the appliance should not be installed Consideration should be given to the requirements of other appliances working in the same room space If other flueless appliances such as cookers are i...

Page 6: ...he coal sits with the 4 coal shapes uppermost and coal profile facing you The feet on the front coal locate between the burner and tags in the burner tray Always secure the door closed after laying th...

Page 7: ...The left hand one coloured red controls On Off and High Low flame The right hand one coloured black is the comfort level thermostat which turns the fire to pilot position once the desired temperature...

Page 8: ...ommencing any servicing ensure that the gas is isolated and the appliance is cool Cleaning The casing should be wiped with a cloth dampened in soapy water The glass may be cleaned with any non abrasiv...

Page 9: ...for their use Using unapproved accessories could prove hazardous and will invalidate the warranty User Instructions Read the instructions before using this appliance This appliance requires installat...

Page 10: ...ry out the lighting procedure to re ignite Cleaning the fuel effect Switch the appliance OFF and allow to cool before commencing The fuels can be accessed by opening the hinged door on the appliance w...

Page 11: ...ured to BS7967 and the test must be carried out in accordance with BS5871 Pt 4 The catalytic converter needs heat to work therefore before you start testing the fire must have been lit and burning on...

Page 12: ...ult the relevant manufacturer Only use replacement catalyst supplied by Burley If you or the customer detects any odours from the fire please remember that the catalytic convertor is not an air filter...

Page 13: ...ant to take a gas rate test over a reasonable period of time so that the capacity of the meter is used On low Input appliances such as our flueless this is even more critical because uncertainties can...

Page 14: ...first year as with all gas products every gas appliances must be serviced every year The appliance has not been subject to misuse accident or repaired or fitted by anyone other than a Gas Safe regist...