2
1
LIGHTING PROCEDURE.
Identify the control valve fitted to the appliance and follow the
appropriate instructions.
1.1
Total Control
Ensure that the ON/OFF switch is in the ON position (
-
) & that the manual knob is also pointing
downwards towards its ON position (see below).
1.2
On the handset simultaneously press and hold the (red circle) and (large flame) buttons
until an acoustic signal confirms the start sequence has begun, then release the buttons.
1.3
The acoustic signal should cease and be replaced with the ticking sound of the spark igniter.
The pilot flame will light & the igniter will stop, another acoustic signal will confirm the pilot has
been established (if the pilot fails to establish repeat the process. Due to the safe & efficient
nature of the fire it is not unusual for this to take two or even three attempts). The acoustic
signal will now cease & the gas rate adjusting knob will automatically turn to its high setting.
1.4
To adjust the gas rate to desired setting press the (large flame) to increase the flame height
or (small flame) to decrease the flame height on the handset.
1.5
To leave the fire in
standby mode
press the (small flame) until the main burner goes out. The
pilot should remain on in this mode & help to reduce condensation.
To turn the fire off completely (including the pilot) press the red OFF button on the handset.
Manual
Knob
Gas Rate
Adjusting
Knob
ON/OFF Switch
NO
M
A
N
O
N
O
FF
Press
these two
buttons
together to
light the
burner
Once lit
use this
button to
increase
gas rate
Once lit
use this
button to
decrease
gas rate