12
7.1.4 A suitable non-combustible support platform shall be constructed within the enclosure for the
appliance to sit upon if required.
7.1.5 Ensure that the wall around the opening and the base are flat and level.
7.1.6 Finally fit a non-combustible back panel against the enclosure and fit the fire surround. Due
note shall be taken of the recommendations specified in section 5.
7.1.7 With the fire box fitted securely into the opening, refit the burner control assembly.
7.1.8 Connect the gas supply pipe to the 8mm compression fitting on the inlet pressure test point
elbow. The complete installation shall be checked for gas tightness using an approved method.
7.1.8 Complete the assembly of the appliance in accordance with section 8.0.
7.2
Installation type 2
Insetting fire into a purpose made opening within the inner leaf of a cavity wall
Infill
panel
Mantle
Inner wall
Cavity
Cavity box
Cavity drip tray
Outer wall
Appliance
Back panel