English
WARNING!
Bodily injury due to escaping liquid
`
`
Close the stopcock completely after dispensing
(set plug to at least „zero“).
`
`
Keep the stopcock closed when it is not in use.
`
`
Do not unscrew the stopcock from the container
when it is filled.
`
`
Empty the stopcock completely before disassembly.
Problem
To eliminate the error
Thread
connection
is not sealed
1. Check transparent LDPE seal for
position.
2. Replace transparent LDPE seal
with softer PE foam gasket (whi-
te) (see accessories).
3. Thread is damaged (contact dealer
or manufacturer).
Stopcock is
dripping
1. Close the plug more tightly.
2. Turn the discharge so it is pointing up.
NOTE!
When used with Bürkle compact jerrycan (see
accessories), remove the transparent LDPE seal
from the sealing flange of the union nut and insert
the PE foam gasket (white) supplied with the
compact jerrycan into the sealing flange inside the
union nut.
`
`
The compact jerrycan is suitable to fill off fluid
and viskosity liquids up to 500 mPas, pay atten-
tion to chemical resistance.
`
`
Constructional changes of the instrument or
the accessories aren‘t allowed. Do not use PTFE
thread sealing tape.
NOTE!
`
`
Only use one seal at a time.
Accessories
More accessories can be found at www.buerkle.de
Type
Specification
Number
Item No.
Compact jerrycan
5 l, with threaded connector 3/4“
1
0435-2050
Compact jerrycan
10 l, with threaded connector 3/4“
1
0435-1100
PE foam gasket
white
1
0006-5055
Venting valve in screw cap
PP/PE
1
0435-9200
Troubleshooting