19
Assembly
Type 8653
7.3
Assembly on standard rail
Caution
risk of injury due to sharp edges.
The earthing plate on the bracket has sharp edges that can cause cuts.
►
Wear suitable protective gloves.
Lever for unlocking the
device from the bracket
Clamping piece
Fastening screw
Fastening screws for
securing to standard rail
Fig. 9:
Assembly on standard rail for AirLINE Field Type 8653 field module
preparatory work
The bracket is connected to the device in the scope of delivery. For assembly on the standard rail, the
device must be released from the bracket.
→
Push back the lever for unlocking the device and at the same time pull the device upwards out of the
bracket.
assembly
→
Observe chapter “Connecting the functional earth for assembly on standard rail” on page
→
Using a slotted-head screwdriver, carefully turn the fastening screws on the bracket all the way
anticlockwise.
→
Position the bracket on the standard rail by tilting it upward slightly and then push it into position on the
standard rail.
→
Using a slotted-head screwdriver, carefully turn the fastening screws on the bracket all the way
clockwise.
The bracket is now secured to the standard rail by the clamping pieces.
→
Slide the guide bars on the field module (see “Fig. 3”) from the top to the bottom into the guide slot of
the bracket (see
“Fig. 4”) until the locking mechanism engages audibly.