Type 1094
22
With a pre-pressure of p
1
= 1 bar and a flow free of back-pressure
(
∆
p = 1 bar), we recommend the following flow settings as
standard values, which you can check on the monitor:
4.3
Standard setting values
NOTE
Monitor signal in mV**
at
Valve type
Start of opening of valve
Full of opening of valve
(
I
1 / Potentiometer R1 )
(
I
2 / Potentiometer R2 )
6021 DN 1.6
135
165
6022 DN 2
260
300
6022 DN 4
210
300
6023 DN 4
420
530
6023 DN 6
340
530
6223 DN10
90
300
6223 DN13
80
330
6223 DN 20
200
530
2821 DN 1,6
125
185
2832 DN 2
285
350
2832 DN 4
175
350
2832 DN 4 EEx *
90
200
2834 DN 4
440
650
2834 DN 6
400
650
2836 DN 10
480
1100
2836 DN 12
430
1100
* pre-pressure 0,5 bar, pressure drop 0,5 bar **
1 mV monitor signal = 1 mA coil current
Connection for the monitor signal:
Cable plug electronics type 1094-PMR
Terminal 5
Monitor signal
Terminal 3
Earth
Normschienenelektronik Typ 1094-PHR
Terminal AN 2-5
Monitor signal
Terminal AN 1-3
Earth