background image

2

Table of Contents

1  The operating instructions ..................................................................................................2
2  Authorized use ..............................................................................................................................3
3  Basic safety instructions.......................................................................................................4
4  Product description ...................................................................................................................6
5  Technical data................................................................................................................................6
6  Installation.........................................................................................................................................8
7  Maintenance, troubleshooting .......................................................................................11
8  Disassembly .................................................................................................................................12
9  Transportation, storage, disposal ................................................................................13

The operaTing insTrucTions

The operating instructions contain important information.

 

Read the instructions carefully and follow the safety instructions.

 

Keep the instructions in a location where they are available to every 

user.

The liability and warranty for Type 0312 are void if the operating 
instructions are not followed. 

1.1  symbols

Danger!

Immediate danger! Serious or fatal injuries.

WarnIng!

Possible danger! Serious or fatal injuries.

CautIon!

Danger! Moderate or minor injuries.

note! 

Warns of damage to property.

english

3

The Type 0312 

 

In a potentially explosive area, the device may be used only in accor-

dance with the specification on the type label. For the use, observe 

the supplementary instructions manual enclosed with the device with 

safety instructions for the explosion-risk area.

 

Devices without a separate Ex type label may not be used in a poten-

tially explosive area.

 

The enclosed UL instructions must be followed in the UL area.

 

used only in conjunction with third-party devices and components 

recommended and authorised by Bürkert.

 

when in perfect condition and always ensure proper storage, trans-

portation, installation and operation.

 

use the device only as intended.

2.1  restrictions

If exporting the device, observe any existing restrictions.

Important tips and recommendations.

Refers to information in these operating instructions or in other 
documentation.

 

Designates instructions for risk prevention.

 

Designates a procedure which you must carry out.

1.2  Definitions of terms

In these instructions, the term “device” always refers to the Type 0312.

auThorizeD use

The Type 0312 is designed for blocking, dosing, filling and 
venting neutral gaseous and liquid media. 

 

Use  according  to  the  authorized  data,  operating  conditions  and 

conditions of use specified in the contract documents and operating 

instructions. 

english

4

2.2  approvals

The  approval  mark  indicated  on  the  Bürkert  type  labels  refers  to  the 
Bürkert products.

 e

 1 

03 5791

Devices which must bear the type approval mark were approved at the 
Kraftfahrtbundesamt under the type approval number

e1*72/245*2006/96*5791*00

and are put into circulation with the indicated type approval mark. You can 
obtain an extract of the type approval from the address below.

Bürkert Werke GmbH 

Zulassungsbeauftragter, 

Christian-Bürkert-Str. 13-17, 

D-74653 Ingelfingen

Basic safeTy insTrucTions

These safety instructions do not make allowance for any contingencies 
and events which may arise during assembly, operation and maintenance.

Risk of injury from high pressure in the system/device.

 

Before working on the system or device, switch off the pressure 

and vent/drain lines.

Risk of injury due to electrical shock.

 

Before working on the system or device, switch off the power supply 

and secure to prevent reactivation.

 

Observe applicable accident prevention and safety regulations for 

electrical equipment.

Risk of burns/risk of fire if used for a prolonged switch-on time 
through hot device surface.

 

Keep device away from highly flammable substances and media and 

do not touch with bare hands.

english

Type 0312

Summary of Contents for 0312

Page 1: ... Internet www burkert com Bedienungsanleitungen und Datenblätter im Internet www buerkert de Manuels d utilisation et fiches techniques sur Internet www buerkert fr Bürkert Werke GmbH Co KG 2014 2017 Operating Instructions 1706 07_EU EN_00893073 Original DE Bürkert Fluid Control Systems Sales Center Christian Bürkert Str 13 17 D 74653 Ingelfingen Tel 49 0 7940 10 91 111 Fax 49 0 7940 10 91 448 E m...

Page 2: ...nformation in these operating instructions or in other documentation Designates instructions for risk prevention Designates a procedure which you must carry out 1 2 Definitions of terms In these instructions the term device always refers to the Type 0312 2 Authorized use The Type 0312 is designed for blocking dosing filling and venting neutral gaseous and liquid media Use according to the authoriz...

Page 3: ...ype Coil power consumption active power in W at operating temperature Pressure range Circuit function Orifice Body material MS brass VA stainless steel Sealing material FKM EPDM NBR 5 1 Conformity The solenoid valve Type 0312 is compliant with the EC Directives according to the EC Declaration of Conformity 5 2 Standards The applied standards which are used to demonstrate compliance with the EC Dir...

Page 4: ...ll a dirt trap to prevent malfunctions Mesh size 0 2 0 4 mm Manifold fastening From above with M4 cylinder head screws before mounting the valves or from below using M5 screws Remove the cover plate Do not mount valves with CFC NC and CFD NO together onto a manifold Warning Risk of injury due to escaping medium Make certain the seals included with delivery are properly seated in the valve Ensure t...

Page 5: ...ched on the pipelines are clean Malfunction Possible cause Valve does not switch Short circuit or coil interrupted Medium pressure outside the permitted pressure range Valve does not close Inner compartment of the valve is dirty If the valve still does not switch please contact your Bürkert Service 8 Disassembly Danger Risk of injury from high pressure in the system device Before working on the sy...

Page 6: ... Internet www burkert com Bedienungsanleitungen und Datenblätter im Internet www buerkert de Manuels d utilisation et fiches techniques sur Internet www buerkert fr Bürkert Werke GmbH Co KG 2014 2017 Operating Instructions 1706 07_DE DE_00893073 Original DE Bürkert Fluid Control Systems Sales Center Christian Bürkert Str 13 17 D 74653 Ingelfingen Tel 49 0 7940 10 91 111 Fax 49 0 7940 10 91 448 E m...

Page 7: ...Informationen in dieser Bedienungsanleitung oder in anderen Dokumentationen markiert eine Anweisung zur Gefahrenvermeidung markiert einen Arbeitsschritt den Sie ausführen müssen 1 2 Begriffsdefinition Der in dieser Anleitung verwendete Begriff Gerät steht immer für Typ 0312 2 BestimmungsgemäSSe Verwendung Der Typ 0312 ist zum Steuern Absperren und Dosieren von neutralen gasförmigen und flüssigen M...

Page 8: ...g in W betriebswarm Druckbereich Wirkungsweise Nennweite Gehäusewerkstoff MS Messing VA Edelstahl Dichtungswerkstoff FKM EPDM NBR 5 1 Konformität Das Magnetventil Typ 0312 ist konform zu den EG Richtlinien entspre chend der EG Konformitätserklärung 5 2 Normen Die angewandten Normen mit welchen die Konformität zu den Richtlinien nachgewiesen wird sind in der EG Baumusterprüfbescheinigung und oder d...

Page 9: ...splatte Von oben mit Zylinderschrauben M4 vor Montage der Ventile oder von unten mit Schrauben M5 Verschlussplatte entfernen Ventile mit WWC und WWD nicht zusammen auf eine Anschlussplatte montieren Warnung Verletzungsgefahr durch Mediumsaustritt Bei mitgelieferten Dichtungen auf den richtigen Sitz im Ventil achten Auf die Ebenheit der Anschlussplatte achten Auf ausreichende Oberflächengüte der An...

Page 10: ...bestimmungen für elektrische Geräte beachten Verbrennungsgefahr Brandgefahr bei längerer Einschaltzeit durch heiße Geräteoberfläche Das Gerät von leicht brennbaren Stoffen und Medien fernhalten und nicht mit bloßen Händen berühren Verletzungsgefahr bei unsachgemäßer Wartungsarbeiten Die Wartung darf nur autorisiertes Fachpersonal mit geeignetem Werkzeug durchführen Anlage vor unbeabsichtigtem Betä...

Page 11: ... Internet www burkert com Bedienungsanleitungen und Datenblätter im Internet www buerkert de Manuels d utilisation et fiches techniques sur Internet www buerkert fr Bürkert Werke GmbH Co KG 2014 2017 Operating Instructions 1706 07_FR FR_00893073 Original DE Bürkert Fluid Control Systems Sales Center Christian Bürkert Str 13 17 D 74653 Ingelfingen Tel 49 0 7940 10 91 111 Fax 49 0 7940 10 91 448 E m...

Page 12: ...mandations importants renvoie à des informations dans ce manuel d utilisation ou dans d autres documentations Identifie une consigne pour éviter un danger Identifie une opération que vous devez effectuer 1 2 Définition des termes Le terme appareil utilisé dans ces instructions désigne toujours le type 0312 2 Utilisation conforme Le type 0312 est conçu pour couper doser remplir et aérer les fluides...

Page 13: ... Puissance de bobine puissance active en W à l état chaud Plage de pression Fonction Diamètre nominal Matériau du corps MS laiton VA acier inox Matériau du joint FKM EPDM NBR 5 1 Conformité L électrovanne type 0312 est conforme aux directives CE conformément à la déclaration de conformité CE 5 2 Normes Les normes utilisées avec lesquelles la conformité avec les directives CE sont prouvées figurent...

Page 14: ...r le cas échéant Installez éventuellement un collecteur de boues comme protection contre les dysfonctionnements Mailles 0 2 0 4 mm Fixation embase Par le haut à l aide de vis à tête cylindrique M4 avant le montage des vannes ou par le bas à l aide de vis M5 Enlevez la plaque de fermeture Ne pas monter les vannes avec la fonction C et D sur la même embase Avertissement Risque de blessures dû à la s...

Page 15: ...ne s enclenche pas Court circuit ou coupure de la bobine Pression du fluide hors de la plage de pression autorisée La vanne ne se ferme pas Intérieur de la vanne encrassé Si malgré tout la vanne ne fonctionne pas veuillez contacter votre service après vente Bürkert 8 Démontage Danger Risque de blessures dû à la présence de haute pression dans l installation l appareil Avant d intervenir dans l ins...

Reviews: