EN
Note:
If several receivers are connected to the same feed line,
then all are simultaneously ready to program.
The heating system begins to briefly light up ‘at random’.
The longer you wait with the programming the greater will
be the offset.
Individual channels/transmitters can now be assigned to
the respective receiver.
You can stop the flashing if you briefly push the
STOP
button of a transmitter which has already been
programmed.
The channel assignment/change can now be made
without you having to disconnect the individual receivers.
Switching on the heating system:
Prerequisite:
The transmitter is programmed.
Press the
UP
or
DOWN
button.
Switching off the heating system:
Press the
STOP
button.
Note:
The radio receiver 2 kW automatically switches the
connected radiant heater off after 12 hours.
3.
4.
The radiant heater
switches between
100 % and 50 % of
its heating power for
2 minutes.
2.
The radio receiver 2 kW now remains in programming mode
for 5 minutes.
The transmitter is programmed.
Switch off/on mains.
Heating switches
off for a short time.
Heating switches off.
Programming possible for max. 16 transmitters.
To program further transmitters, proceed as follows:
1.
2.
3.
The transmitter is programmed.
Programming additional transmitters
Programmed transmitter
Heating switches off
for a short time.
Heating switches off.
Hints for transmitter assignment:
• Before commencing with the programming of the first transmitter,
it is recommended to wait a few ON/OFF cycles in order to adjust
yourself to the cycle.
• Do not press any transmitter buttons without reason as long as the
receiver is still in programming mode.
• If receivers are unnecessarily in programming mode, then this can
be aborted by pressing the
Stop
button on a programmed hand-held
transmitter.
1.
Briefly press
the program-
ming button
P.
Press the ▲ button
within the first
2 sec. of the pro-
gramming phase
during the 100 %
heating cycle.
Press the ▼
button
within
the first 2 sec.
of the program-
ming phase
during the 50 %
heating cycle.
Press the buttons
for approx.
3 sec.
The heating system
alternates between
100 % and 50 %
heating power for
2 minutes.
Press the
▲ button
within
the first 2 sec.
of the program-
ming phase
during the 100 %
heating cycle.
Press the
▼ button
within
the first 2 sec.
of the program-
ming phase
during the 50 %
heating cycle.
I M P O R T A N T !
The heating system can only be switched off
completely by unplugging the mains plug of the
radiant heater.
!
!
and
or
Schematic diagram of the following
programming procedure
Heating OFF
(random duration)
Heating OFF
(durable and ready for operation
Heating ON (100%)
(press nothing)
Heating ON 50
%
(5 seconds)
Press the
▼ button
during the programming
phase
Press the ▲ button
during the programming
phase
Duration
2 minutes
Heating OFF
(random duration)
Heating ON 100
%