background image

Repair parts may be ordered from your authorized point of sale or from

BUR-CAM PUMPS

STEP  3

Prepare your choice 

of discharge pipe size 

and check valve

STEP  4

Install your pump in 

the center of the pit

STEP  5

Install discharge 

in pipe

STEP  6

Connect float and 

motor power cable

STEP  7

Fill the basin 

and test the 

operation

STEP  8

Review and check 

connections for leaks

SUMP PUMP APPLICATION

REPAIR PARTS

STEP  2

Sump pit 18’’ diameter 

X 25’’ depth

REF.   PART   

DESCRIPTION

450444AG  Vertical Float Switch

310196 

Float Bracket

310197 

Screws (4)

4  

310198 

Stainless Steel 

 

 

 

Hexagone Bolts (4)

310199 

Complete Motor

6 350277  Adapter

7 310200  Impeller

310201 

Pump Base

5

Summary of Contents for 300735

Page 1: ...s secure and vertical for proper operation 4 Assure that there is adequate clearance from any combustible materials or structure Stored materials must be kept away from the pump Shelves or cabinet str...

Page 2: ...uming that you have a sump pit located in your basement floor Your sump pit must be constructed from concrete brick tile or more recently a sump basin made from plastic and or fiberglass The minimum s...

Page 3: ...en pit is ready proceed to next step STEP 1 STEP 2 Application This submersible sump pump is designed for a permanent sump installation It can be used in light commercial application and is great for...

Page 4: ...n extension cord to connect your pump to the power source From your distribution panel to the receptacle we recommend a wire gauge not smaller than 14 gauge Use tape or tie wrap to fix power cords to...

Page 5: ...pipe STEP 6 Connect float and motor power cable STEP 7 Fill the basin and test the operation STEP 8 Review and check connections for leaks SUMP PUMP APPLICATION REPAIR PARTS STEP 2 Sump pit 18 diamete...

Page 6: ...r Improper float position Check movement Pump does not Jammed impeller Clean deliver to full Plugged check valve Clean replace capacity Blocked suction inlet Check for debris in pit and clean Discharg...

Page 7: ...ion verticale pour un fonctionnement ad quat 4 Assurez vous que tout mat riel ou structure combustible est suffisamment loign de la pompe Tout mat riel entrepos doit tre tenu l cart de la pompe Les st...

Page 8: ...limentation de la prise Assumant que vous avez une fosse dans votre sous sol Votre fosse doit tre construite de b ton briques tuiles ou bassin de plastique et ou de fibre de verre La dimension minimal...

Page 9: ...lation permanente Elle peut tre utilis e pour une application commerciale l g re Elle est tr s efficace pour ass cher les endroits inond s Capacit 5 4000 GPH US 10 3300 GPH US 15 2650 GPH US 20 1580 G...

Page 10: ...ique la prise nous recommandons un calibre minimal de 14 Utiliser du ruban gomm ou des attaches pour c bles et fixer les c bles lectriques au tuyau de d charge Emplir la fosse ou le bassin avec de l e...

Page 11: ...s c bles d alimentation de la flotte et de la pompe TAPE 7 Emplir le bassin et v rifier le fonctionnement TAPE 8 R vis et v rifier les joints APPLICATION DE POMPE PUISARD PI CES DE RECHANGE TAPE 2 Bas...

Page 12: ...eux Remplacer Flotte bloqu e V rifier le mouvement Le d bit n est Impulseur bloqu Nettoyer pas pleine Clapet de retenue bloqu Nettoyer remplacer capacit Succion bloqu e V rifier les d bris et nettoyer...