We recommend that you install your pump in a clean location where there is adequate 

room for servicing at a later date. Protection from freezing temperatures and good 

ventilation should be considered as well, to provide the pump an environment for 

long life. 

Do not use to pump gas or toxic fuels. This submersible sump pump is 

designed to pump water only.

 

 Friction losses in the discharge pipe must be taken into consideration when the 

horizontal offset is greater than 50 feet. The discharge pipe should be increased from 

1  1/2”  to  2”. This  will  reduce  friction  losses  and  allow  the  pump  to  give  maximum 

performance.

 

 More friction losses must also be taken into consideration when many elbows and 

fittings are installed in the discharge line. Each elbows and fittings must be considered 

as 1 feet of head. 

 

 The float switch of your pump has been pre-set at the factory and does not need any 

adjustment.

 

Never run the pump dry.

 Damage to the seal may occur. Fill pump pit or sump  

 

basin with water before turning on the power.

 

 Assuming that you have a sump pit located in your basement floor... Your sump pit 

may be constructed from concrete, brick, tile or more recently a sump basin made 

from plastic and/or fiberglass. The minimum size of your sump pit should be 18” in 

diameter and no less than 25” deep. When pit is ready, proceed to next step.

STEP  1

STEP  2

Application

   

This submersible sump pump is designed for 

a permanent sump installation. It can be used 

in light commercial application and is great for 

water transfer from flodded areas.

  

Capacity

:

 

  5’   

4000 US GPH 

 

10’   

3300 US GPH 

 

15’   

2650 US GPH 

 

20’   

1580 US GPH 

Features 

 Cast iron pump body 

 Stainless steel motor body 

 Stainless steel mechanical rotary seal 

 Thermal and overload protection 

 Oil filled motor

 

 1/2HP, 115VAC, 60Hz, 6.3A, (12.0A when start)

Friction loss in pipe  

not included

3

INSTALLATION STEPS

  

Please note before you proceed with the installation of this product that the 

manufacturer’s guideline 

has to

 be respected. Failure to comply may void your 

warranty.

The following are minimum requirements in order to protect your residence from flooding. It is a small 

investment but it is your personal responsibility to protect your home, family and valuables. Failure to 

comply with the following requirements may also void your warranty:

•    Two (2) pumps 

have to

 be installed in the sump pit. The first pump as a primary pump and the second 

pump as the backup unit.

•   Burcam alarm system model 450454

 has to

 be installed to advise you of any malfunctions.

•    As sump pumps are electrically powered and activated so to prevent flooding, a Burcam battery 

powered back up pump model 300403 

has to

 be installed to evacuate the water. 

Pump selection, proper and adequate installation are a must to comply with local by-laws and need to be 

adhered to.

IMPORTANT NOTICE

Summary of Contents for 300735

Page 1: ...s secure and vertical for proper operation 4 Assure that there is adequate clearance from any combustible materials or structure Stored materials must be kept away from the pump Shelves or cabinet str...

Page 2: ...uming that you have a sump pit located in your basement floor Your sump pit must be constructed from concrete brick tile or more recently a sump basin made from plastic and or fiberglass The minimum s...

Page 3: ...en pit is ready proceed to next step STEP 1 STEP 2 Application This submersible sump pump is designed for a permanent sump installation It can be used in light commercial application and is great for...

Page 4: ...n extension cord to connect your pump to the power source From your distribution panel to the receptacle we recommend a wire gauge not smaller than 14 gauge Use tape or tie wrap to fix power cords to...

Page 5: ...pipe STEP 6 Connect float and motor power cable STEP 7 Fill the basin and test the operation STEP 8 Review and check connections for leaks SUMP PUMP APPLICATION REPAIR PARTS STEP 2 Sump pit 18 diamete...

Page 6: ...r Improper float position Check movement Pump does not Jammed impeller Clean deliver to full Plugged check valve Clean replace capacity Blocked suction inlet Check for debris in pit and clean Discharg...

Page 7: ...ion verticale pour un fonctionnement ad quat 4 Assurez vous que tout mat riel ou structure combustible est suffisamment loign de la pompe Tout mat riel entrepos doit tre tenu l cart de la pompe Les st...

Page 8: ...limentation de la prise Assumant que vous avez une fosse dans votre sous sol Votre fosse doit tre construite de b ton briques tuiles ou bassin de plastique et ou de fibre de verre La dimension minimal...

Page 9: ...lation permanente Elle peut tre utilis e pour une application commerciale l g re Elle est tr s efficace pour ass cher les endroits inond s Capacit 5 4000 GPH US 10 3300 GPH US 15 2650 GPH US 20 1580 G...

Page 10: ...ique la prise nous recommandons un calibre minimal de 14 Utiliser du ruban gomm ou des attaches pour c bles et fixer les c bles lectriques au tuyau de d charge Emplir la fosse ou le bassin avec de l e...

Page 11: ...s c bles d alimentation de la flotte et de la pompe TAPE 7 Emplir le bassin et v rifier le fonctionnement TAPE 8 R vis et v rifier les joints APPLICATION DE POMPE PUISARD PI CES DE RECHANGE TAPE 2 Bas...

Page 12: ...eux Remplacer Flotte bloqu e V rifier le mouvement Le d bit n est Impulseur bloqu Nettoyer pas pleine Clapet de retenue bloqu Nettoyer remplacer capacit Succion bloqu e V rifier les d bris et nettoyer...