Page 9
TROUBLESHOOTING (cont.)
PROBLEM
Inconsistent beverage level in dis-
penser (cont.)
Consistently low beverage level in
the dispenser (ST, STF, STA &
STFA)
Spitting or excessive steaming
PROBABLE CAUSE
3. Syphon system
4. Lime build-up
CAUTION -
Tank and tank compo-
nents should be delimed regularly
depending on local water condi-
tions. Excessive mineral build-up
on stainless steel surfaces can ini-
tiate corrosive reactions resulting
in serious leaks.
5. Water pressure (ST, STF, STA
& STFA)
1. Timer
2. Strainer/flow control (.222
GPM)
1. Lime build-up
CAUTION -
Tank and tank compo-
nents should be delimed regularly
depending on local water condi-
tions. Excessive mineral build-up
on stainless steel surfaces can ini-
tiate corrosive reactions resulting
in serious leaks.
2. Control thermostat
REMEDY
The brewer must be level or slightly
lower in front to syphon properly.
Inspect the tank assembly for ex-
cessive lime deposits. Delime as
required.
The water pressure to the brewer
must be at least 20 psi (138 kPa).
(A) Early models-Timer dial must
indicate at least two minutes and
fifteen seconds.
(B) Refer to
Service - Digital Timer
for testing procedures. See page
24
(A) Direction of flow arrow must
be pointing towards brewer.
(B) Remove the strainer/flow con-
trol and check for obstructions.
Clear or replace.
Inspect tank assembly for exces-
sive lime deposits. Delime as re-
quired.
Refer to
Service - Control Ther-
mostat for testing procedures. See
page 14
29251 052500
Summary of Contents for S
Page 31: ...Page 31 29251 052500 ...
Page 32: ...Page 32 29251 052500 ...
Page 33: ...Page 33 29251 052500 ...
Page 34: ...Page 34 29251 052500 ...
Page 35: ...Page 35 29251 052500 ...
Page 36: ...Page 36 29251 052500 ...
Page 37: ...Page 37 29251 052500 ...
Page 38: ...Page 38 29251 052500 ...
Page 39: ...Page 39 29251 052500 ...
Page 40: ...Page 40 29251 052500 ...
Page 41: ...Page 41 29251 052500 ...
Page 42: ...Page 42 29251 080400 ...
Page 43: ...Page 43 29251 052500 ...
Page 44: ......