TROUBLESHOOTING (cont.)
PROBLEM
Beverage overflows dispenser
(cont.)
Weak beverage
Dry coffee grounds remain in the
funnel
Brewer is making unusal noises
(ST, STF, STA & STFA)
PROBABLE CAUSE
3. Solenoid valve (ST, STF, STA &
STFA)
1. Filter type
2. Coffee grind
3. Sprayhead
4. Funnel loading
5. Water temperature
1. Funnel loading
1. Solenoid valve
2. Plumbing lines
REMEDY
Remove the Solenoid Valve and
clean any obstruction. Rebuild or
replace the valve if necessary. See
page 18
The BUNN® paper filter must be
used for proper extraction.
A fine or drip grind must be used
for proper extraction.
A six-hole stainless steel spray-
head must be used for proper
extraction.
The BUNN® paper filter must be
centered in the funnel and the bed
of ground leveled by gentle shak-
ing.
Place an empty funnel on an empty
dispenser beneath the sprayhead.
Initiate a brew cycle and check the
water temperature immediately
below the sprayhead with a ther-
mometer. The reading should not
be less than 195
°
F. Adjust the
control thermostat to increase the
water temperature. Replace if nec-
essary.
The BUNN® paper filter must be
centered in the funnel and the bed
of grounds leveled by gently shak-
ing.
The nut on the solenoid must be
tight or it will vibrate during op-
eration.
Plumbing lines should not resting
on the counter top.
29251 052500
Summary of Contents for S
Page 31: ...Page 31 29251 052500 ...
Page 32: ...Page 32 29251 052500 ...
Page 33: ...Page 33 29251 052500 ...
Page 34: ...Page 34 29251 052500 ...
Page 35: ...Page 35 29251 052500 ...
Page 36: ...Page 36 29251 052500 ...
Page 37: ...Page 37 29251 052500 ...
Page 38: ...Page 38 29251 052500 ...
Page 39: ...Page 39 29251 052500 ...
Page 40: ...Page 40 29251 052500 ...
Page 41: ...Page 41 29251 052500 ...
Page 42: ...Page 42 29251 080400 ...
Page 43: ...Page 43 29251 052500 ...
Page 44: ......