Page 19
CALIBRATE FLOW?
NO YES
CALIBRATE DILUTION?
NO YES
CONTAINER READY?
NO YES
DILUTION CTS 64oz
(-) #### (+)
Displays number of pulses counted by flow meter to dilution nozzle.
May be adjusted using +/- if you know the flow rate.
This function provides a 60 second test mode to capture water from the
sprayhead or dilution nozzle. This measurement will then give you the num-
bers to enter into the "SPRAY OZ/M: xx" screen.
("SPRAY OZ/M:
will
not display when "BrewLogic" is enabled)
NOTE: Should be performed after deliming and/or changing sprayhead.
Choice of calibrating dilution, or by selecting "NO" can calibrate sprayhead.
Place measuring container of at least one gallon capacity under the dilution
nozzle or sprayhead as needed.
Screen shot during the test run. Actual numbers will vary.
Take the reading captured in container and enter into this screen using the +/-.
Press "DONE" to save the number.
CALIBRATE DILUTE
FLOW COUNT ###
PROGRAMMING (cont.)
BREW COUNTERS?
NO YES
Tracks the total number of brew cycles completed. There is one reset-able
counter, and one life counter that is not reset-able
ENTER oz ##.#
(-) DONE (+)