Bunn Infusion Series Installation & Operating Manual Download Page 19

Page 19

CALIBRATE FLOW?

NO                      YES

CALIBRATE DILUTION?

NO                     YES

CONTAINER READY?

NO                      YES

DILUTION CTS   64oz

(-)        ####        (+)

Displays number of pulses counted by flow meter to dilution nozzle. 

May be adjusted using +/- if you know the flow rate.

This function provides a 60 second test mode to capture water from the 

sprayhead or dilution nozzle. This measurement will then give you the num-

bers to enter into the "SPRAY OZ/M:  xx" screen.

  

("SPRAY OZ/M:

 

will 

not display when "BrewLogic" is enabled)
NOTE:
 Should be performed after deliming and/or changing sprayhead.

Choice of calibrating dilution, or by selecting "NO" can calibrate sprayhead.

Place measuring container of at least one gallon capacity under the dilution 

nozzle or sprayhead as needed.

Screen shot during the test run. Actual numbers will vary.

Take the reading captured in container and enter into this screen using the +/-.

Press "DONE" to save the number.

CALIBRATE DILUTE

FLOW COUNT   ###

PROGRAMMING (cont.)

BREW COUNTERS?

NO                     YES

Tracks the total number of brew cycles completed. There is one reset-able 

counter, and one life counter that is not reset-able

ENTER oz   ##.#

(-)         DONE        (+)

48497.2 111017

Summary of Contents for Infusion Series

Page 1: ...0002A 12 17 2017 Bunn O Matic Corporation To ensure you have the latest revision of the Operating Manual Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quickest way to obtain the latest catalog and manual updates For Technical Service contact Bunn O Matic Corporation at 1 800 286 6070 ...

Page 2: ...tatements by such individuals whether oral or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that the equipment does not conform to the warranty BUNN at its exclusive op tion while the equipment is under warranty shall either 1 provide at no charge replacement parts and or labor during the applicable parts and labor warranty periods spe...

Page 3: ...res are Energy Savings mode BUNNLink compatible Freshness Timer and Sanitation Alert The brewer can also be programmed to adjust different functions of the brewing process such as brew temperature brew volumes pulse brew etc This allows the operator to program a certain recipe for each tea or coffee flavor to be brewed CONTENTS Warranty 2 Introduction 3 User Notices 4 Electrical Requirements 4 Nor...

Page 4: ... Refer to Data Plate on the Brewer and local national electrical codes to determine circuit requirements WARNING The brewer must be disconnected from the power source until specified CAUTION Improper electrical installation will damage electronic components Damage caused by incor rect electrical connections is not covered by warranty 1 An electrician must provide electrical service with L14 30R re...

Page 5: ...d in applications such as farm houses Access to the service areas permitted by Authorized Service personnel only The A Weighted sound pressure level is below 70 dBA NORTH AMERICAN REQUIREMENTS This appliance must be installed in locations where it can be overseen by trained personnel For proper operation this appliance must be installed where the temperature is between 41 F to 95 F 5 C to 35 C App...

Page 6: ... Bunn O Matic does not recommend the use of a reverse osmosis or deionized water supply to this equipment REQUIRED 2 0 gpm 7 57 lpm flow rate from water supply line NOTE Bunn O Matic recommends 3 8 copper tubing for all installations from the 1 2 water supply line A tight coil of tubing in the water line will facilitate moving the brewer to clean the countertop Bunn O Matic does not recommend the ...

Page 7: ...g this switch will begin a brew cycle on the selected side D PROGRAMMING right Pressing and holding this switch allows entry into the programming menus Pressing and releasing the switch steps through each function screen while in the programming mode E BATCH SELECTOR SWITCHES Pressing the switch corresponding to the Half or Full batch selects the amount of product to be brewed on the selected side...

Page 8: ...3 3 93 3 93 3 93 3 93 3 93 3 93 3 93 3 92 8 92 2 91 7 91 1 90 6 90 6 90 0 89 4 88 9 88 3 87 8 87 2 86 7 86 1 85 6 35665 0000A 05 04 2004 Bunn O Matic Corporation 213 8 212 9 212 0 211 1 210 2 209 3 208 4 207 4 206 5 205 6 204 7 203 8 202 9 201 9 201 0 200 1 199 2 198 3 197 4 196 5 195 5 194 6 193 7 1000 500 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000 8500 9000 ...

Page 9: ...entrate step is complete and to press the respective brew button again 9 Following the brew will be a countdown of drip time DRIPPING which shows the time remaining until the tea no longer drips from the funnel tip 10 Pressing the respective brew button again will begin the dilution process the display will read NOW BREW ING and show time remaining in brew cycle The display will also show DILUTION...

Page 10: ...ction in Level 1 All other functions are accessed in Level 2 The following function screens are in order of appearance Each screen will have instructions on how to access and the procedures for programming the various functions of the brewer IMPORTANT PROGRAMMING NOTES READ CAREFULLY To exit the programming mode at any time press and release either ON OFF pad located on the front switch panel The ...

Page 11: ...ECIPE NO YES SET TEMP 200 DONE READY DEGREE 5 DONE ENABLE ADS NO DONE YES ENABL ENERGYSAVR NO DONE YES ENABLE BREW LOGIC NO DONE YES CALIBRATE FLOW NO YES ENTER SERVICE NO YES BREW LOCKOUT NO DONE YES NO YES FACTORY DEFAULTS NO YES SERVICE TOOLS DILUTION CTS 64oz BREW COUNTERS NO YES ENABLE SANITATION NO DONE YES CALIBRATE LP1 LP2 NO YES XX REFILL XXX DONE ENTER ASSET NO YES 48497 2 111017 ...

Page 12: ...ys will be different ex Brew oz will become Brew Liters F will be C This function has two parts 1 It allows the operator to view the brew settings for the various recipes stored into the brewer 2 It allows the operator to modify change any of the brew settings for a particular recipe stored in the brewer Procedure for reviewing the recipes 1 Press and hold the right hidden switch until the display...

Page 13: ...MANUAL method jump to step 28 Setting Pulse Brew EASY Pulse Brew Range Minimum will adjust to the minimum time required to brew that batch using the set brew volumes and flow rate for the sprayhead Maximum will adjust depending on settings and will always be minimum time 3 minutes The brewer will automatically calculate what the 1ST ON TIME OFF TIMES and LAST ON TIME will be using THE INITIAL ON T...

Page 14: ...l also be blinking 43 Using or set the amount of time from when the brew spray ends to when the funnel is emptied of hot liquid 44 When finished press the other batch size and repeat step 43 45 When finished setting both batch sizes press and release DONE The display should read 2 BATCHES DONE 46 Select YES The screen should show the name of the recipe being programmed modified along with SETUP CO...

Page 15: ...reen 4 If NO was selected the display should now read ENTER SER VICE To exit programming and return to the MAIN SCREEN press and release the ENABLE BREW ON OFF switch 5 If YES was selected the display should now read NEW AD This screen allows you to write a new ad 6 The display should now read 2 LINES 16 CHARS AVAILABLE and then SCROLTHRU ALPHA NEXT NEXT LETTER and then WRITE TOP LINE The ad can b...

Page 16: ...o the NEW AD screen To exit programming and return to the MAIN SCREEN press and release the ENABLE BREW ON OFF switch 18 To correct or edit the ad press and release EDIT The display should now read WRITE TOP LINE Repeat steps 10 though 17 19 To save the ad as it is shown press and release YES The display should now read ADVER TISEMENT SETUP COMPLETE and then ENTER SERVICE To exit programming and r...

Page 17: ...electing NO warns of accuracy risk Select CAL to start calibration procedure Selecting OK will skip to level probe calibration screen Automatically checks to see if tank temperature is between 130 170 F 54 76 C Go to SPRAY OZ M Go to CAL LP1 LP2 PRESS BREW WHEN CONTAINER READY Verify brew funnel and decanter airpot thermal server depending on which model you have are in place Then press the BREW S...

Page 18: ... as the level probe calibration Brewer must not be bumped during calibration Machinewilldispensevolumebetweenupperprobeandlowerprobe4times The total dispense will be about half of a decanter Brewer must not be bumped during calibration Enter volume dispensed into container Use the to increase the numeric value or to decrease Displays sprayhead flow rate and volume of water between the upper and lo...

Page 19: ...n BrewLogic is enabled NOTE Shouldbeperformedafterdelimingand orchangingsprayhead Choice of calibrating dilution or by selecting NO can calibrate sprayhead Place measuring container of at least one gallon capacity under the dilution nozzle or sprayhead as needed Screen shot during the test run Actual numbers will vary Takethereadingcapturedincontainerandenterintothisscreenusingthe Press DONE to sa...

Page 20: ...release the NEXT switch to move to the next digit in the phone number 4 Repeat Step 3 until the entire number is entered 5 Press and release the DONE switch The display will now read EXITING BrewWIZARD and then ENTER PASSWORD ENTER SERVICE NO YES FACTORY DEFAULTS NO YES SERVICE TOOLS NO YES Allows the testing of individual components and the ability to check the membrane switches for proper functi...

Reviews: