Page 21
PROGRAMMING THE BREWER (cont.)
* ENABLE ENERGY SAVER
This function allows the operator to enable the ENERGY
SAVINGS mode function and set the idle time. Once
the set idle time has expired, the operator can choose
to have the heaters
either turn off, or reduce the tank
holding temp to 140° F (60° C).
Procedure to enable energy savings mode:
Range: 0.5 to 24.0 hrs
If enabled, default setting is 140° F (60° C) tank tem-
perature after 4.0 hrs. idle time.
1. Press and hold the right hidden switch until the
display reads SET LANGUAGE. Press and release the
right hidden switch until the display reads ENABLE
ENERGYSAVR. The YES or NO will be flashing to
indicate the current selection.
2. Select NO to disable or:
3. Select YES to enable this function.
4. When finished, press and release DONE to save the
new setting and advance to the next screen.
5. If NO was selected, the display should now read
EnableFreshTimer. To exit programming and return
to the MAIN SCREEN, press ENABLE BREW ON/
OFF switch.
6. If YES was selected, the display should now read
X.X HRS -> IDLE. This screen allows the operator
to set the amount of time the brewer is not in use
before energy save mode engages. Using (-) and (+),
adjust the idle time. When finished, select DONE.
7. The display should now read AFTER IDLE TIME?
Once the set idle time has expired, the heaters can
either be shut off or held at 140° F.
8. To have the heaters shut off after the set idle time,
select OFF and then DONE to save the settings.
The display should read MACHINE OFF AFTER X.X
HRS, and then EnableFreshTimer.
9. To have the temperature reduce to 140° F, select
140° and then DONE to save the settings. The display
should read MACHINE AT 140° AFTER X.X HRS,
and then EnableFreshTimer.
10. Once the idle time has expired, the display will
read either ENERGY SAVER...NO TEMPERATURE
or ENERGY SAVER...REDUCED TEMPERATURE,
depending on the settings. This screen will alternate
with PRESS ANY SWITCH TO RE-HEAT.
* ENABLE FRESH TIMER
This function allows the operator to enable the Freshness
Alert and set the expiration time. The expiration time is
the amount of time the product is allowed to sit in the
server/dispenser before a fresh batch is brewed.
Procedure for enabling/setting the Freshness Timer:
Range: Coffee 0.5 to 4.0 hrs
Hot Tea 0.5 to 8.0 hrs
If enabled, default setting is 2.0 hrs. for Coffee and 2.0
hrs. for Hot Tea.
1. Press and hold the right hidden button until the
display reads SET LANGUAGE. Press and release
the right hidden button until the display reads EN-
ABLE FRESHTIMER.
2. Select NO to disable or:
3. Select YES to enable this function (the unit will dis-
play a message once the set time has expired).
4. When finished, select DONE to save the new setting
and advance to the next screen.
5. If NO was selected, the display should now read
REFILL. To exit programming and return to the
MAIN SCREEN, press either ENABLE BREW ON/
OFF switch.
6. If YES was selected, the display should now read
COFFEE. This screen allows the operator to set the
amount of time from the end of brewing a batch
of coffee until a Freshness Alert message will be
displayed. Using (-) and (+), adjust the freshness
time for coffee. When finished, select DONE.
7. The display should now read HOT TEA. Using (-)
and (+), adjust the freshness time for hot tea. When
finished, select DONE.
8. This display should now read REFILL. To exit pro-
gramming and return to the MAIN SCREEN, press
ENABLE BREW ON/OFF switch.
9. Once the set time has expired, the display will read
FRESHNESS ALERT BREW (A,B or C), and then
FRESHNESS ALERT BREW FRESH BATCH alternat-
ing with the MAIN SCREEN.
10. Empty the server/dispenser the previous batch was
brewed into and replace under the funnel.
11. Brew a new batch
12. The freshness timer will reset. The display should
now return to the MAIN SCREEN.
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
41581.2 091609