Page 23
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
PROGRAMMING THE BREWER (cont.)
2. If the actual flow rate of the nozzle is known but is
different than the number on the display, use the
(-) and (+) to enter the correct flow rate.
3. When finished, select DONE. This saves the new
setting and advances to the next screen, CALIBRATE
FLOW. To exit programming and return to the MAIN
SCREEN, press ENABLE BREW ON/OFF switch.
NOTE: If the flow rate is unknown, proceed to the
CALIBRATE FLOW screen.
* CALIBRATE FLOW
This function allows the operator to test and enter the
actual flow rate of the sprayhead(s) and the bypass/
dilution for each side of the brewer by dispensing each
separately for one minute. The volumes are then entered
into the brewer.
Procedure to calibrate the sprayhead flow rate:
1. Place a container, accurately graduated with a mini-
mum capacity of 60 ounces, under the funnel.
2. Press and hold the right hidden switch until the
display reads SET LANGUAGE. Press and release
the right hidden switch until the display reads
CALIBRATE FLOW?
3. Select YES to advance to SPRAY HEAD CAL screen.
(Selecting NO in the CALIBRATE FLOW screen will
advance to BREW COUNTERS).
4. Select YES.
The display should read CONTAINER READY? If
container is under the funnel, select YES.
5. The display should read CALIBRATE SPRAY. Press
and release any BREW button on the side to be cali-
brated to begin the sprayhead flow for calibration.
The display should read CALIBRATE SPRAY...60
SEC TO FINISH. The 60-second timer on the display
will count down to zero. When the counter reaches
zero, the display will change to LEFT or RIGHT OZ,
along with a number.
6. Measure the amount of water in the container and
use (-) and (+) to match the display to the amount
in the container. Then select DONE.
7. The display should now read NEW L or NEW R
SPRY FLOW, along with the correct flow rate of
the sprayhead. After about 5 seconds, the display
will return to the CALIBRATE FLOW screen.
8. Repeat steps 1-7 to calibrate the other side.
9. To exit the CALIBRATE FLOW function and advance
to the next screen, select NO. To exit programming
and return to the MAIN SCREEN, press either EN-
ABLE BREW ON/OFF switch.
Procedure to calibrate the bypass flow rate:
(ICB)
1. Place a container, accurately graduated with a mini-
mum capacity of 60 ounces, under the funnel.
2. Press and hold the right hidden switch until the
display reads SET LANGUAGE. Press and release
the right hidden switch until the display reads
CALIBRATE FLOW?
3. Select YES to advance to SPRAY HEAD CAL screen.
Select NO to advance to BYPASS CAL.
4. Select YES.
The display should read CONTAINER READY? If
container is under the funnel, select YES.
5. The display should read CALIBRATE BYPASS. Press
any BREW button on the side to be calibrated to
begin the flow for calibration. The display should
read CALIBRATE BYPASS...60 SEC TO FINISH. The
60-second timer on the display will count down to
zero. When the counter reaches zero, the display
will change to LEFT or RIGHT OZ/M, along with a
number.
6. Measure the amount of water in the container and
using the (-) and (+), adjust the amount on the
display to match the amount in the container. Then
select DONE.
7. The display should now read NEW L or NEW R
BYPS FLOW, along with the correct flow rate of
the bypass. After about 5 seconds, the display will
return to the CALIBRATE FLOW screen.
8. Repeat steps 1-7 to calibrate the other side.
9. To exit the CALIBRATE FLOW function and advance
to the next function screen, select NO. To exit pro-
gramming and return to the MAIN SCREEN, press
ENABLE BREW ON/OFF switch.
Procedure to calibrate the dilution flow rate:
(ITCB)
1. Place a container, accurately graduated with a mini-
mum capacity of 130 ounces, under the funnel.
(cont. on page 24)
41581.2 091609