10
TROUBLESHOOTING (cont.)
PROBLEM
Water is not hot (Cont.)
Spitting or excessive steaming
Dripping from dispense tip
Water flows into tank continuously
PROBABLE CAUSE
4. Tank Heater Switch
5. Relay (120V versions only)
6. Control Board #2 (120V versions
only)
1. Lime build-up
CAUTION -
Tank and tank compo-
nents should be delimed regularly
depending on local water condi-
tions. Excessive mineral build-up on
stainless steel surfaces can initiate
corrosive reactions resulting in seri-
ous leaks.
2. Control Thermostat
1. Lime build-up
CAUTION -
Tank and tank compo-
nents should be delimed regularly
depending on local water condi-
tions. Excessive mineral build-up on
stainless steel surfaces can initiate
corrosive reactions resulting in seri-
ous leaks.
2. Dispense Solenoid Valve
1. Control Board #1 and Probe
2. Solenoid Valve (Inlet)
REMEDY
Refer to
Service
- Tank Heater
Switch for testing procedures. See
page 39
Refer to
Service
- Relay for testing
procedures. See page 40
Refer to
Service
- Control Board
#2 for testing procedures. See page
22
Inspect the tank assembly for ex-
cessive lime deposits. Delime as
required.
Refer to
Service
- Control Thermo-
stat for testing procedures. See
page 19
Inspect the tank assembly for ex-
cessive lime deposits. Delime as
required.
Remove the dispense solenoid valve
and clear any obstructions. Rebuild
or replace the valve if necessary.
See page 35
Refer to
Service -
Control Board
and Probe for testing procedures.
See page 20
Refer to
Service
- Solenoid Valve
(Inlet) for testing procedures. See
page 37
35135 012103